OMRON E5EN-HAA2HHBFM-500 100-240 VAC E5EN-HAA2HHBFM-500 100-240 VAC E5EN7202F E5ENHAA2HHBFM500AC100240 OMRON Universal input 2 ps aux HB trif. Sa.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

E5EN-HAA2HHBFM-500 100-240 VAC E5EN7202F E5ENHAA2HHBFM500AC100240 OMRON Universal input 2 ps aux HB trif. Sa..

E5EN-HAA2HHBFM-500 100-240 VAC

E5EN7202F

E5ENHAA2HHBFM500AC100240

OMRON

1 Pcs.

Universal input 2 ps aux HB trif. Salt. Transfer 48x96 Temp. controller, PROplus, ,1/4 DIN, (48 x 96)mm,2 x OUT option,2 x Aux OUT,HT Burnout SSR Fail./3Phs.,Event I/P & Transf. OUT,option unit,100-240V AC

Automation > Temperature monitoring relay
E5EN-H

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Omron advanced temperature controller (E5EN-HAA2HHBFM-500 100-240 VAC) delivers high-performance regulation for demanding industrial thermal processes requiring multi-zone management or heater burnout alarms. This controller integrates seamlessly into large electrical panels to maintain tight temperature tolerances across continuous operations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Voltage type (operating voltage) (EF005294): AC
  • Type of electric connection (EF003961): Screw connection
  • Voltage type (supply voltage) (EF002991): AC
  • Error registration possible (EF003423): No
  • External reset possible (EF003426): No
  • With detachable clamps (EF003340): No
  • Number of contacts as change-over contact (EF008257): 0
  • Number of contacts as normally open contact (EF008256): 2
  • Width (EF000008): 96 mm
  • Number of contacts as normally closed contact (EF008255): 0
  • Number of measuring circuits (EF003425): 1
  • Height (EF000040): 96 mm
  • Depth (EF000049): 60 mm
  • Supply voltage AC 50 Hz (EF007532): 100 V
  • Supply voltage AC 60 Hz (EF007533): 100 V

More info

▲
Size1/8 DIN (96 x 48 mm)FunctionsHB/HS alarm for 3-phase heaters, ON/OFF control, PID controlNumber of control loops1Temperature input typeB, C (WRe5-26), E, J, JPt100, K, L, N, P (PLII), Pt100, R, S, T, ULinear analog input type0 to 10 V, 0 to 20 mA, 0 to 5 V, 1 to 5 V, 4 to 20 mATemperature range-200-2300 °CFeaturesRemote SP, Transfer outputNumber of event inputs2Number of alarm outputs2Supply voltage AC100-240 VControl outputLinear current, Linear voltage, Relay, Voltage pulseTerminal typeScrew

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.