OMRON G7S-3A3B-E DC24 G7S-3A3B-E DC24 G7SE0001G G7S3A3BEDC24 OMRON Relay Safety 3PST-NA 3PST-NC 6-pole 10A 24vdc View larger
Images are for illustrative purposes only. Please refer to data sheet for details

G7S-3A3B-E DC24 G7SE0001G G7S3A3BEDC24 OMRON Relay Safety 3PST-NA 3PST-NC 6-pole 10A 24vdc

G7S-3A3B-E DC24

G7SE0001G

G7S3A3BEDC24

OMRON

20 Pcs.

Relay Safety 3PST-NA 3PST-NC 6-pole 10A 24vdc Safety relay, plug-in, 3PST-NO, 3PST-NC, 10 A, forcibly-guided contacts, 24 VDC

Automation > Switching relay
G7S

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A safety relay is a critical electromechanical device implemented in machine safeguarding systems to monitor emergency stops, safety gates, and light curtains. The Omron G7S-3A3B-E DC24 uses interlocked contact architecture to ensure reliable fault detection and prevent dangerous machine operation should a contact weld shut. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Standard: Flux-tight
  • 3PST-NO, 3PST-NC: G7S-3A3B-E
  • Track-mounting: Track mounting and screw mounting possible
  • Back-mounting: PCB terminals
  • 24 VDC: 30
  • Rated load: NO contact; NC contact: 6 A at 250 VAC, 6 A at 30 VDC
  • Rated carry current: NO contact; NC contact: 6 A
  • Maximum switching voltage: 250 VAC, 30 VDC
  • Maximum switching current: NO contact; NC contact: 6 A
  • Continuous current: 10 A
  • Dielectric strength: 2000 VAC for 1 min. between terminals
  • Insulation resistance: 1000 MΩ min. 3
  • Ambient operating humidity: 25 to 85%

More info

▲
  • Forcibly guided contacts
  • Conforms to EN 50205
  • NO contacts: 10 A at 250 VAC and 10 A at 30 VDC, NC contacts: 6 A at 250 VAC and 6 A at 30 VDC (for resistive loads)
  • Reinforced insulation between inputs and outputs and poles
  • 4- and 6-pole relays available

Specifications & ordering info

Ordering information

Relays with forcibly guided contacts

Type

Sealing

Poles

Contacts

Rated voltage

Order code

Standard

Flux-tight

6 poles

4PST-NO, DPST-NC

24 VDC

G7S-4A2B-E

3PST-NO, 3PST-NC

G7S-3A3B-E

Sockets

Type

LED indicator

Rated voltage

Order code

Track-mounting

Track mounting and screw mounting
possible

Yes

24 VDC

P7S-14F-END

Back-mounting

PCB terminals

No

-

P7S-14P-E

Specifications

Ratings

Coil

Rated voltage

Rated current (mA)1

Coil resistance (Ω)1

Max. voltage (V)2

Power consumption (W)

24 VDC

30

800

110%

Approx. 0.8

Contacts

Item

Resistive load

Rated load

NO contact

10 A at 250 VAC, 10 A at 30 VDC

NC contact

6 A at 250 VAC, 6 A at 30 VDC

Rated carry current

NO contact

10 A

NC contact

6 A

Item

Resistive load

Maximum switching voltage

250 VAC, 30 VDC

Maximum switching current

NO contact

10 A

NC contact

6 A

G7S-_-E Characteristics of Sockets

Model

P7S-14F-END

P7S-14P-E

Continuous current

10 A

Dielectric strength

2000 VAC for 1 min. between terminals

Insulation resistance

1000 MΩ min.3

Ambient operating humidity

25 to 85%

5 to 85%

Characteristics

Contact resistance4

100 mΩ max.

Operating time5

50 ms max.

Release time2

50 ms max.

Maximum operating frequency

Mechanical

18,000 operations/h

Rated load

1,800 operations/h

Insulation resistance

100 MΩ min.

Durability6

Mechanical

10,000,000 operations min. (at approx. 18,000 operations/h)

Electrical

100,000 operations min. (at the rated load and approx. 1,800 operations/h)

Inductive load switching capability7(IEC60947-5-1)

NO Contact

AC15 AC240V 5A, DC13 DC24V 2A

NC Contact

AC15 AC240V 3A, DC13 DC24V 2A

Ambient operating temperature

-25 to 70°C (with no icing or condensation)

Ambient operating humidity

5% to 85%

Note: The values listed above are initial values.

Please check Omron in the Internet for updated information on product reliability data and the SISTEMA libraries: http://industrial.omron.eu/safety


1.The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.

2.The maximum voltage is based on an ambient operating temperature of 23°C maximum.

3.Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.

4.Measurement conditions: 5 VDC, 10 mA, voltage drop method.

5.Measurement conditions: Rated voltage operation, ambient operating temperature: 23°C, contact bounce time is not included.

6.The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.

7.AC15: cosφ= 0.3, DC13: L/R = 96-ms


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.