An Omron Class IV Advanced PLe Hand 1870mm serial Connection functions as a presence-sensing safety device designed to protect operators from hazardous machinery by creating an optical light curtain around dangerous zones. Such safety light curtains are deployed on industrial automation lines to instantly halt mechanical motion whenever the protected field is breached. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Finger protection: Dia. 14 mm
- Hand/arm protection: Dia. 30 mm
- 0.2 to 7 m: 1,745 to 2,495
- 26: 245
- 28: 263
- 34: 317
- 42: 389
- 50: 461
- 60: 551
- 68: 623
- 76: 695
- 80: 731
- 88: 803
- 96: 875
- 108: 983
- 116: 1,055
More info
▲- For simple and affordable hand protection
- Easy to install
- Mounting now takes less than half the man-hours that conventional models take.
Specifications & ordering info
Ordering information
Safety light curtain model list
F3SJ-A14 series (9 mm gap), F3SJ-A14 TS series (9 mm gap)
Protective height (mm)1 | ||
|---|---|---|
F3SJ-A30 series (25 mm gap)
Protective height (mm)2 | ||
|---|---|---|
Accessories (sold separately)
Single-end connector cable (2 cables per set, for emitter and receiver)
For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller.
Setting Tools
Connector cap (1), |
Sensor Mounting Brackets (Sold separately)
Laser pointer
Specifications
F3SJ-A____P14/P30
Response Time
Note: Use the following expressions for series connection.
- •For 2-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit - 1 (ms), Response time (OFF to ON): Response time calculated by the above × 4 (ms) - •For 3-set series connection:
Response time (ON to OFF):
Response time of the 1st unit + Response time of the 2nd unit + Response time of 3rd unit - 5 (ms), Response time (OFF to ON): Response time calculated by the above × 5 (ms)
For models with the “-TS” suffix, multiply the response time obtained by the above × 5 (ms), or use 200 ms, whichever is less.) - •For 4-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit + Response time of the 3rd unit + Response time of the 4th unit - 8 (ms)
Response time (OFF to ON): Response time calculated by the above × 5 (ms)
Cable extension length
Total cable extension length must be no greater than the lengths described below.
When the F3SJ and an external power supply are directly connected, or when the F3SJ is connected to a G9SA-300-SC.
Using incandescent lamp for auxiliary output and external indicator output | ||||
When connected to the F3SP-B1P
Note: Keep the cable length within the rated length. Failure to do so is dangerous as it may prevent safety functions from operating normally.
Connections
Basic Wiring Diagram
PNP Output
Wiring when using manual reset mode, external device monitoring.