View larger
S8V-CP0824 S8V 1005E S8VCP0824 OMRON Electronic circuit breaker, 8 channels, max. 10 A per channel, 24 VDC
S8V-CP0824
S8V 1005E
S8VCP0824
OMRON
1 Pcs.
Automation > Accessories/spare parts for low-voltage switch technology
S8V Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for intelligent power distribution protection, the Omron S8V-CP0824 electronic circuit breaker provides multi-channel overcurrent monitoring and selective load tripping in 24 VDC control circuits. Electronic protective units of this standard prevent widespread system downtime by selectively isolating faulted branches while maintaining supply to healthy lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 04: 4 outputs
- 08: 8 outputs
- 24: 24 VDC
- S: Yes
- No: No
- 4 outputs: No
- Yes: S8V-CP0424S
- 8 outputs: No
- I/O characteristics: Rated inputvoltage (Input voltage allowable range)
- Max. ratedoutput current (per output): 10 A
- Output leakagecurrent: 10 mA max.
- When all output branches are tripped: 0.84 W typ.
- Start-up delay time: 50 ms to 5 s
- Functions 2 Referto Cat. No. T226-E1 for details.: Currenttripping function 2 Refer to Cat. No. T226-E1for details.
- Cutoff current: 2.5 A, 3.5 A, 4.5 A, 6.5 A, 8.5 A, 10.5 A
- Push button(ON/OFF/RESET) with indicator: Yes (LED colors: Red/Green/Yellow)
More info
▲- 4- / 8-channel electronic circuit breakers with adjustable tripping currents from 2 to 10 A
- Thermomagnetic tripping characteristic
- Sequential and load-dependent start-up of the outputs to avoid high inrush currents
- Ability to switch-on high capacitive loads reliably
- Backlit buttons with multi-color LEDs indicate the output status at a glance
- Push-In Plus terminal blocks
- Space saving Value Design for Panel
- UL Class 2 model reduces the costs of applying a safety standard
Specifications & ordering info
Ordering information
ModelNumber Structure
Model Number Legend
Notall combinations are possible. Refer to List of Models in OrderingInformation, below.
(1) Number of Outputs
| Code | Number of Outputs |
|---|---|
| 04 | 4 outputs |
| 08 | 8 outputs |
(2) Rated input voltage
| Code | Rated input voltage |
|---|---|
| 24 | 24 VDC |
(3) UL Class 2 output
| Code | UL Class 2 output certified |
|---|---|
| S | Yes |
| No | No |
List of Models
Unit
| Number of Outputs | UL Class 2 output | Order code |
|---|---|---|
| 4 outputs | No | S8V-CP0424 |
| Yes | S8V-CP0424S | |
| 8 outputs | No | S8V-CP0824 |
Specifications
| Item | Model Number ofOutputs UL Class 2 output | S8V-CP0424 | S8V-CP0424S | S8V-CP0824 | |
|---|---|---|---|---|---|
| 4 | 4 | 8 | |||
| No | Yes | No | |||
| I/O characteristics | Rated inputvoltage (Input voltage allowable range) | 24 VDC (20 to 30 VDC) | 24 VDC (20 to 28.8 VDC) | 24 VDC (20 to 30 VDC) | |
| Allowableinput current 2 For power input terminals, use 35 A max. per pole. | 40 A | 15.2 A | 70 A | ||
| Max. ratedoutput current (per output) | 10 A | 3.8 A | 10 A | ||
| Internalvoltage drop 2 A voltage drop will occur in the S8V-CP. Considerthe voltage drop at the output. | 200 mV max. | 150 mV max. | 200 mV max. | ||
| Output leakagecurrent | 10 mA max. | ||||
| Power consumption 2 Whenselecting the power supply, be sure to include the internal powerconsumption of the S8V-CP and not just the power consumption ofthe load. | When all outputs are connected | 10 W max. (at 10 A) | 3.1 W max. (at 3.8 A) | 20 W max. (at 10 A) | |
| When all output branches are tripped | 0.84 W typ. | 0.82 W typ. | 1.32 W typ. | ||
| Start-uptime 2 Outputs start in order from +VO1 to +VO8. +VO1 starts afterthe initialization time. Start-up delay time of each output is automaticallydecided depending on the load. If the start-up delay time is over5 s, the next output is forcibly started. | Initialization time | 250 ms typical | |||
| Start-up delay time | 50 ms to 5 s | ||||
| Functions 2 Referto Cat. No. T226-E1 for details. | Currenttripping function 2 Refer to Cat. No. T226-E1for details. | Rated output current | 2 A, 3 A, 4 A, 6 A, 8 A, 10 A | 3.8 A | 2 A, 3 A, 4 A, 6 A, 8 A, 10 A |
| Cutoff current | 2.5 A, 3.5 A, 4.5 A, 6.5 A, 8.5 A, 10.5 A | 3.8 A | 2.5 A, 3.5 A, 4.5 A, 6.5 A, 8.5 A, 10.5 A | ||
| Over voltagetripping function 2 Refer to Cat. No. T226-E1for details. | No | Yes | No | ||
| Push button(ON/OFF/RESET) with indicator | Yes (LED colors: Red/Green/Yellow) | ||||
| Reset signalinput (RST) | Yes (High level: 15 to 30 VDC,Low level: 0 to 5 VDC) | ||||
| Alarm signaloutput (ALM1/ALM2) | Yes (MOS FET relay output 30 VDCmax., 50 mA max.) | ||||
| Insulation | Dielectricstrength | 1.0 kVAC for 1 min (between allterminals and DIN rail mounting parts), current cutoff 20 mA | |||
| Insulationresistance | 100 MΩ min. (between all terminalsand DIN rail mounting parts) at 500 VDC | ||||
| Environment | Ambient operatingtemperature | –25 to 70°C (Derating is requiredaccording to the temperature.) (with no condensation or icing) | |||
| Storage temperature | –40 to 85°C (with no condensationor icing) | ||||
| Ambient operatinghumidity | 5% to 96% (storage humidity: 5%to 96%) | ||||
| Vibrationresistance | 10 to 55 Hz, maximum 5 G, 0.42mm half amplitude for 2 h each in X, Y, and Z directions | ||||
| Shock resistance | 294 m/s2, 3 times each in ±X,±Y, ±Z directions | ||||
| Reliability | MTBF 2 MTBFis calculated according to JEITA RCR-9102. | 13,5000 hrs typ. | 60,000 hrs typ. | 13,5000 hrs typ. | |
| Life expectancy 2 Referto Cat. No. T226-E1 for details. | 10 years min. | ||||
| Construction | Weight | 160 g max. | 170 g max. | 420 g max. | |
| Cooling fan | No | ||||
| Degree ofprotection | IP20 by EN/IEC 60529 | ||||
| Standards | EMI | Conforms to EN 61000-6-3 | |||
| EMS | Conforms to EN 61000-6-2 | ||||
| Safety standards | UL 508 (CSA22.2 No.14-10) Listing Pol2 UL 2367 Recognition (Max. 100W per output, per Class 2 limitations) Pol2 2 UL Class 2 output applies for the S8V-CP0424S model only. CE (EN 61000-6-2, EN 61000-6-3) | ||||