Electrode holders |
|---|
Applications | Mounting style | Insulator material | Max. temperature | Number of electrodes | Order code |
|---|
For city water and other general use. Easy-to-replace separate versions for maintenance. | Flange | Phenol resin | 70°C | 3 | PS-3S |
When mounting space is limited. Special 3pole holder of small size and light weight. | Screw | Phenol resin | 3, 300 mm 3, 1,000 mm | PS-31-300MM PS-31-1000MM |
Use for sewage, sea water, etc., having a low specific resistance. | Flange | PPS | 150°C (without water drips or vapour on the electrode holder surface) | 1 | BF-1 |
For resistance to high pressure. Use in tanks with high temperature or pressure. | Screw | PFA | 250°C (without water drips or vapour on the surface of the electrode holder) | 1 | BS-1 |
Electrode separators | Number of electrodes | Order code |
| 1 | F03-14 1P |
3 | F03-14 3P |
Electrodes, connecting, and lock nuts |
Applicable liquids | Material | Component | Indication mark | Inscription | Order code |
Purified city water, industrial water, sewage | Equivalent to SUS 304 (AISI-304) | Electrode (1 m long) | 1 line | − | F03-01 SUS201 |
Connecting nut | − | − | F03-02 SUS201 |
Lock nut | − | − | F03-03 SUS201 |
Purified city water, industrial water, sewage, dilute alkaline solution | SUS316 (AISI-316) | Electrode (1 m long) | 2 lines | − | F03-01 SUS316 |
Connecting nut | − | 6 | F03-02 SUS316 |
Lock nut | − | 316 | F03-03 SUS316 |
Item | 61F-GP-N8 | 61F-GP-N8L | 61F-GP-N8H | 61F-GP-N8D | 61F-GP-N8R |
|---|
Supply voltage | 24, 100, 110, 120, 200, 220, 230 or 240 VAC; 50/60 Hz |
Operating voltage range | 85 to 110% of rated voltage |
Interelectrode voltage | 8 VAC | 24 VAC | 8 VAC |
Interelectrode current | Approx. 1 mA AC max. | Approx. 0.4 mA AC max. | Approx. 1 mA AC max. |
Power consumption | Approx. 3.5 VA max. |
Response time | Operate: 80 ms max., release: 160 ms max. |
Cable length | 1 km max. | 2 km max. 4 km max. | 50 m max. | 1 km max. | 800 m max. |
Control output | 1 A, 250 VAC (inductive load: cosφ = 0.4), 3 A, 250 VAC (resistive load) |
Ambient temperature | Operating: −10 to 55°C |
Life expectancy | Electrical: 100,000 operations min., mechanical: 5,000,000 operations min |
Size in mm (H×W×D) | 49.9×38×70 |