View larger
F3S-TGR-NLMX-21-10 AA040403D F3STGRNLMX2110 OMRON Switch Sec. PLe Long Metal ATEX 2NC+1NO 10m
F3S-TGR-NLMX-21-10
AA040403D
F3STGRNLMX2110
OMRON
1 Pcs.
Automation > Position switch with separate actuator
Contactless Switches TGR
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Omron F3S-TGR-NLMX-21-10 is a safety switch engineered for heavy-duty industrial environments requiring reliable interlock monitoring of protective barriers. Such devices prevent machine startup while safety guards remain open, protecting personnel from active mechanical hazards in hazardous areas. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 10 m pre-wired: 2NC/1NO
- 10 m pre-wired: 2NC/1NO
- Serial switching: up to 6 pcs.
- Operating distance: OFF ON (Sao); ON OFF (Sar): 22 mm open
- Actuator approach speed: Min. Max.
- Enclosure protection: Flying lead
- Switching current: Min.
- Rated loads: NC contacts NO contact
- for F3S-TGR-NBMX: F39-TGR-NBMX-A
- Spacer (8 mm, Set of 2pcs.) 1: for F3S-TGR-NLMX
- Construction type housing (EF004008): Cuboid
- Degree of protection (IP) (EF005474): IP67
- Type of electric connection (EF003961): With cable preassembled
- Housing material (EF001596): Metal
- Explosion safety category for gas (EF003997): ATEX gas-ex-protection, Cat. 2G
More info
▲Explosion proof non-contact switches
Explosion proof reed non-contact switches monitor the status of guarding doors in petrochemical and food applications with explosive atmospheres.
- Based on reed technology
- Connect up to 6 switches in series
- Operates with all Omron safety controllers
- Operates behind stainless steel fittings
- Non-contact – no abrasion – no particles
- Compensation of mechanical tolerances
- Suitable for high pressure cleaning, CIP/SIP processes
- Conforms to safety categories up PLe acc. EN ISO13849-1
- For use in hazardous areas IECEx and ATEX EExd IIC T6 (Gas and Dust). Designed for Petro-chemical and food applications where explosive atmospheres are present.
Ordering information
Elongated sensors
Barrel sensors
Specifications
Mechanical data
IP 67 Certification for IP67 but can be used for SIP/CIP and high pressure cleaning like IP69K) | |||
Electrical data
Ex specification
II 2G Ex mb IIC T6Gb, II 2D Ex mb IIC T80 Db IP67* |
Approved standards
Accessories
Set of Torx safety screws | ||
Spacer (8 mm, Set of 2pcs.)1 | ||
Wiring examples (Single head connection)
G9SASingle sensor application with G9SA-301 | ||||