E5C2Basic temperature controllers
Easy-to-use, basic temperature controller with analog dial setting
Omron's basicON/OFF or PD controllerfeaturesan analogsettingdial. This compact, low-cost controller has a setting accuracy of 2% of full scale. It incorporates a plug-in socket allowingfor DIN-rail or flush mounting.
• Compact, cost-effective controller
• Control mode: ON/OFF or P
• Control output: relay
• Power supply: 100 to 240 VAC
• Thermocouple K: 0 to 1200°C, J: 0 to 400°C, Pt100: –50to 400°C
Ordering information
Standard models (Power supply: 100 to 240 VAC)
Input Control method On/OFF Proportional (P) Output/Indication methodRelay/No indication
Input/ standard scale (°C)
Thermocouple K (CA) Chromel vs. Alumel 0 to 200 °CE5C2-R20K AC100-2400-200E5C2-R40K AC100-240 0-200
0 to 300 °C –E5C2-R40K AC100-240 0-300
0 to 400 °CE5C2-R20K AC100-2400-400E5C2-R40K AC100-240 0-400
0 to 600 °CE5C2-R20K AC100-2400-600E5C2-R40K AC100-240 0-600
0 to 800 °CE5C2-R20K AC100-2400-800E5C2-R40K AC100-240 0-800
0 to 1000°CE5C2-R20K AC100-2400-1000–
0 to 1200°CE5C2-R20K AC100-2400-1200– J (IC) Iron versus Constantan0 to 200 °C E5C2-R20J AC100-240 0-200–
0 to 300 °C E5C2-R20J AC100-240 0-300–
0 to 400 °C E5C2-R20J AC100-240 0-400– Resistance thermometer Platinum resistance thermometer –50 to 50 °C E5C2-R20P-D AC100-240 -50-50 –
0 to 50 °C E5C2-R20P-D AC100-240 0-50–
0 to 100 °C E5C2-R20P-D AC100-240 0-100–
0 to 200 °C E5C2-R20P-D AC100-240 0-200–
0 to 300 °C E5C2-R20P-D AC100-240 0-300–
0 to 400 °C E5C2-R20P-D AC100-240 0-400– ThermistorTHE (replaceable element)0 to 100 °C E5C2-R20G AC100-240 0-100 –
100 to 200 °CE5C2-R20G AC100-240 100-200 –
150 to 300 °CE5C2-R20G AC100-240 150-300 –
Input rangesThermocouple *1
Platinum resistance thermometer Thermistor *2
K (CA) chromel vs. alumelJ (IC) iron vs. constantanPt100 THE
°C0 to 200 (5),
0 to 400 (10),
0 to 600 (20),
0 to 800 (20),
0 to 1,000 (25),
0 to 1,200 (25)
*1Values in ( ) are the minimum unit.
*2Values in ( ) are the thermistor resistive value.
Accessories
0 to 200 (5),
0 to 300 (10),
0 to 400 (10)
–50 to 50 (2),
0 to 50 (1),
0 to 100 (2),
0 to 200 (5),
0 to 300 (10),
0 to 400 (10)
0 to 100 (2) (6 k at 0°C),
100 to 200 (2) (550 @ 200°C)
150 to 300 (2) (4 k @ 200°C)
Functions Order code Front connecting socket with finger protection P2CF-08-E Back connectingsocket (for flush mounting) P3G-08
Finger protection cover (for P3G-08)Y92A-48G
Protectivefront cover (IP66)Y92A-48B
517
E5C2Basic temperature controllers
Specifications
Supply voltage 100 to 240VAC, 50/60 Hz Thermocouple input typeK, J (with sensor break detection) RTD input type Pt100, THE
Control mode ON/OFF or P control
Setting methodanalog setting
Output Relay, SPDT, 3 A at 250 VAC
Life expectancyElectrical: 100,000 operations min.
Setting accuracy±2%FS max. HysteresisApprox.0.5% FS (fixed) Proportional band3% FS (fixed)
Reset range5 ±1%FS min.
Control period20 s
IP Rating front panelIP40 (IP66 cover available)
IP rating terminals IP00
Ambient temperature –10 to 55°C
Size in mm (HxWxD)48×48×96
518
| Feature Name | Feature Value |
|---|---|
| Voltage type (operating voltage) (EF005294) | AC |
| Type of electric connection (EF003961) | Plug-in connection |
| Voltage type (supply voltage) (EF002991) | AC |
| Error registration possible (EF003423) | No |
| External reset possible (EF003426) | No |
| With detachable clamps (EF003340) | No |
| Number of contacts as change-over contact (EF008257) | 1 |
| Number of contacts as normally open contact (EF008256) | 0 |
| Width (EF000008) | 48 mm |
| Number of contacts as normally closed contact (EF008255) | 0 |
| Number of measuring circuits (EF003425) | 1 |
| Height (EF000040) | 48 mm |
| Depth (EF000049) | 101.7 mm |
| Supply voltage AC 50 Hz (EF007532) | 100 V |
| Supply voltage AC 60 Hz (EF007533) | 100 V |