View larger
A4E-B200VA A4E 0007F A4EB200VA OMRON Switch activation plastic 3pos 2sal activation
A4E-B200VA
A4E 0007F
A4EB200VA
OMRON
1 Pcs.
Automation > Agreement switch
Others
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This switch activation plastic component serves as an interface element in industrial automation setups, supporting reliable signal routing and control logic. Devices of this type are routinely integrated into machinery control panels and safety circuits to govern electrical pathways. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Two contacts: 1NC (grip output)
- 2 (Semi- conductors): 2 (Semi- conductors)
- Spring-cage terminals: G9SX-GS226-T15-RC
- Rated supply voltage: 24 VDC
- Safety input: Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ
- Auxiliary output: PNP transistor output Load current: 100 mA max.
- Type of switching contact (EF003591): Quick-break switch
- Degree of protection (IP) (EF005474): IP65
- Type of electric connection (EF003961): Flat plug-in connection
- With status indication (EF001602): No
- Suitable for safety functions (EF001597): Yes
- Forced opening (EF006694): Yes
- Number of extra push buttons (EF009213): 0
- Number of contacts as change-over contact (EF008257): 0
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 0
More info
▲- An optional Holding Key (sold separately) provides a versatile method for selecting modes.
- Equipped with conduit connector
- Positive operating feel - Original double snap action switch mechanism lets the operator precisely confirm the enable position.
- Safety circuits are easy to configure - Safety circuits can be easily configured by combining the A4EG with the G9SX-GS Safety Guard Switching Unit.
Specifications & ordering info
Ordering information
Enabling grip switches
Safety guard switching units
Safety outputs1 | Auxiliary outputs2 | Max. OFF | ||||||
|---|---|---|---|---|---|---|---|---|
OFF-delayed4 | ||||||||
Specifications
Ratings of guard switching unit
Power input
Inputs
Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ | |
Outputs
Application example
Automatic switching mode
Worker is loading and unloading the machine manually. When loading is finished, robot cycle is started manually by the worker. When robots return to their home position, loading cycle is selected automatically.
Loading condition: Safety sensor B is not active, safety sensor A is active because the robots are not allowed to move to the loading area while the worker loads the machine. So the worker is safe because safety sensor A is active.
Robot work condition: Safety sensor B is active, safety sensor A is not active because the worker is not allowed to move to the loading area when the robots work. So the worker is safe because safety sensor B stops the machine if he moves to the loading area.
Manual switching mode
Worker has to do maintenance in this machine. While maintenance, it is necessary to move the machine in a limited way. The worker has to select automatic mode or manual mode manually by using the mode selector switch.
Operation steps:
1) Select maintenance mode by using the mode selector
2) Open the door to do the maintenance while the machine still is able to operate in a limited way (monitoring of limited movement by using the safety limit switch).
3) Close the cover after finishing maintenance
4) Select automatic mode by using the mode selector
E-Stop conditions:
a) open the door while not in maintenance mode
b) the machine actuates the limit switch (breaks the limit).
c) the Enabling grip switch A4EG is actuated to stop the machine in emergency condition.