| Primary task cycle time | 2 ms |
| Program memory | 1.5 MB |
| Variables memory | 2 MB |
| Max. number of synchronous axes | 4 |
| Max. number of PTP axes | 4 |
| Number of digital inputs | 24 |
| Input type | PNP/NPN |
| Number of digital outputs | 16 |
| Output type | NPN |
| Number of serial option boards | 2 |
| Max. number of expansion units | 8 |
| Max. number of remote I/O nodes | 16 |
| Communication port(s) | EtherCAT Master, EtherNet/IP, Ethernet TCP/IP |
| Number of Ethernet ports | 2 |
| Number of USB ports | 0 |
| Communication option(s) | Serial RS-232C, Serial RS-422, Serial RS-485 |
| Real-time clock | |
| Supply voltage DC | 20.4-28.8 V |
| Product Height (unpacked) | 100 mm |
| Product Width (unpacked) | 148 mm |
| Product Depth (unpacked) | 71 mm |
| Product Weight (unpacked) | 650 g |
| CJ1W-BAT01 | Battery for CJ1M PLCs | ||
| GX-JC03 | 3-port EtherCAT Junction module, 24 VDC power supply | ||
| GX-JC06 | 6-port EtherCAT Junction module, 24 VDC power supply | ||
| GX-JC06-H | 6-port EtherCAT Junction module, 24 VDC power supply, with node switches | ||
| HMC-SD493 | SD memory card, 4 GB | ||
| NX-PF0730 | NX I/O power feed unit, 5-24 V DC input, 8 terminals, 10A, screwless push-in connector, 12mm wide | ||
| NX1W-ADB21 | Sysmac NX1P Analog I/O screwless option board, 2 x analog inputs 0 to 10 V, resolution 1/4000 or 0 to 20 mA, resolution 1:2000 | ||
| NX1W-CIF01 | Sysmac NX1P RS-232C screwless (15 m max.) serial communication option board | ||
| NX1W-CIF11 | Sysmac NX1P RS422/485 screwless (50 m max.) serial communication option board | ||
| NX1W-CIF12 | Sysmac NX1P RS422/485 screwless (isolated 500 m max.) serial communication option board | ||
| NX1W-DAB21V | Sysmac NX1P Analog I/O screwless option board, 2 x analog outputs 0 to 10 V, resolution 1:4000 | ||
| NX1W-MAB221 | Sysmac NX1P Analog I/O screwless option board, 2 x analog inputs 0 to 10 V, resolution 1:4000 or 0 to 20 mA, resolution 1:2000, 2 x analog outputs 0 to 10 V, resolution 1:4000 | ||
| SYSMAC-SE201L | Sysmac Studio license. 1 Single user. | ||
| W4S1-05D | 5-port enhanced Ethernet switch | ||
| XS6W-6LSZH8SS100CM-Y | Ethernet patch cable, F/UTP, Cat.6A, LSZH (Yellow), 1 m | ||
| XS6W-6LSZH8SS200CM-B | Ethernet patch cable, F/UTP, Cat.6A, LSZH (Blue), 2 m | ||
| XS6W-6LSZH8SS200CM-Y | Ethernet patch cable, F/UTP, Cat.6A, LSZH (Yellow), 2 m | ||
| XS6W-6LSZH8SS20CM-Y | Ethernet patch cable, F/UTP, Cat.6A, LSZH (Yellow), 0.2 m | ||
| XS6W-6LSZH8SS500CM-Y | Ethernet patch cable, F/UTP, Cat.6A, LSZH (Yellow), 5 m | ||
| XS6W-6LSZH8SS50CM-Y | Ethernet patch cable, F/UTP, Cat.6A, LSZH (Yellow), 0.5 m |
| Feature Name | Feature Value |
|---|---|
| Performance level according to EN ISO 13849-1 (EF007399) | Level a |
| Model (EF000010) | Compact |
| SIL according to IEC 61508 (EF009889) | None |
| Voltage type (supply voltage) (EF002991) | DC |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Type of memory (EF002996) | FLASH |
| Radio standard UMTS (EF008525) | No |
| Supporting protocol for EtherCAT (EF017564) | Yes |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Supporting protocol for other bus systems (EF003062) | Yes |
| Supporting protocol for SERCOS (EF006657) | No |
| IO link master (EF007298) | No |
| Rack-assembly possible (EF007018) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for IEC 60870 (EF016069) | No |
| Supporting protocol for EtherNet/IP (EF007521) | Yes |
| Supporting protocol for DNP3 (EF016068) | No |
| Radio standard GSM (EF008524) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for IEC 61850 Ethernet (EF015389) | No |
| Suitable for rail mounting (EF003972) | Yes |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| System accessory (EF004118) | No |
| Certified for UL hazardous location class III (EF017627) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Radio standard GPRS (EF008523) | No |
| Certified for UL hazardous location class II (EF017625) | No |
| Certified for UL hazardous location class I (EF017622) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for TCP/IP (EF003050) | Yes |
| Wall mounting/direct mounting (EF007020) | Yes |
| Front built-in possible (EF007016) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Additional program memory possible (EF003029) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Supporting protocol for Modbus (EF003057) | Yes |
| Redundancy (EF003156) | No |
| Certified for UL hazardous location group G (non-conductive dusts) (EF017639) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) | No |
| Radio standard Bluetooth (EF007178) | No |
| Suitable for safety functions (EF001597) | No |
| Certified for UL hazardous location group E (metal dusts) (EF017637) | No |
| With display (EF000458) | No |
| With optical interface (EF003028) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Radio standard WLAN 802.11 (EF007179) | No |
| Certified for UL hazardous location group A (acetylene) (EF017632) | No |
| Certified for UL hazardous location division 2 (EF017629) | No |
| Certified for UL hazardous location division 1 (EF017628) | No |
| Certified for UL hazardous location group D (propane) (EF017636) | No |
| Supporting protocol for ASI (EF003051) | No |
| Certified for UL hazardous location group C (ethylene) (EF017635) | No |
| Certified for UL hazardous location group B (hydrogen) (EF017633) | No |
| Number of HW-interfaces other (EF003027) | 2 |
| Memory size (EF002997) | 3500 kByte |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of relay outputs (EF007348) | 0 |
| Number of HW-interfaces USB (EF003025) | 0 |
| Width (EF000008) | 148 mm |
| Number of digital inputs (EF001992) | 24 |
| Depth (EF000049) | 71 mm |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of analogue inputs (EF001994) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of digital outputs (EF001993) | 16 |
| Number of HW-interfaces industrial Ethernet (EF003020) | 2 |
| Number of analogue outputs (EF001995) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Processing time (1K, binary operation) (EF003004) | 0.0033 ms |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Height (EF000040) | 100 mm |
| Supply voltage DC (EF007534) | 20.4 V |