View larger
NX-TBA082 NX020085B NXTBA082 OMRON Replacement screwless push-in connector with 8 wiring terminals (marked A..
NX-TBA082
NX020085B
NXTBA082
OMRON
1 Pcs.
Automation > Accessories/spare parts for controls
Machine I/O NX-series
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Omron NX-TBA082 replacement screwless push-in connector (part number NX-TBA082) delivers reliable termination points for field wiring on modular automation racks, featuring eight dedicated wire terminals. Terminal blocks of this style are integrated into industrial I/O nodes to speed up device installation and maintenance without the need for tools. Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Communication coupler: EtherNet/IP Slave
- Safety controller: NX-Bus
- Safety Digital Input: 4 inputs + 2 test outputs; 8 inputs + 2 test outputs: Free Run
- Safety Digital Output: 2 outputs, 2.0 A; 4 outputs, 0.5 A: Free Run
- Type of electrical accessory/spare part (EF005722): Plug
- Accessory (EF013236): No
- Spare part (EF013237): Yes
More info
▲NX Stand-alone Safety Controller
NX-Safety Stand-alone is a powerful, modular and easily commissioned safety controller which, due to its scalability, can be efficiently adapted to the requirements of a wide variety of safety applications. Thanks to this modular and expandable hardware, the compact safety controller grows with its task slice-by-slice – right up to the highest safety level. You can grow up to 256 I/O points in one single Safety CPU. The design of safe system solutions is thus considerably simplified.
- The system meets PLe according to the EN ISO 13849-1 and SIL3 according to the IEC 61508 and Cat.4
- Safety Function Blocks conforming with IEC 61131-3 standard programming
- Programming with Sysmac Studio software tool
- EtherNet/IP connectivity

Communication and control units
| Max. 512 bytes in + 512 bytes out Supports local safety communication | |||||
| 512 KB Safety program capacity |
Safety digital I/O units
Performance1, I/O Refresh Mode | |||||
|---|---|---|---|---|---|
Note:For selecting the compatible NX Digital and Analog I/O units, please refer to the NX-series modular I/O system chapter from this catalogue, check the Sysmac Studio Software I/O edition software tool or visit our website. As this selection is technically not easy, is better to contact our Omron support.