OMRON LFV3-100RD(A) LFV3-100RD(A) AA054078G LFV3100RDA OMRON Coaxial LED light, network, active area: 102 mm x 100 mm, 24 VDC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

LFV3-100RD(A) AA054078G LFV3100RDA OMRON Coaxial LED light, network, active area: 102 mm x 100 mm, 24 VDC

LFV3-100RD(A)

AA054078G

LFV3100RDA

OMRON

1 Pcs.

Coaxial LED light, network, active area: 102 mm x 100 mm, 24 VDC

Automation > Accessories/spare parts for sensor technology
Special

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Omron LFV3-100RD(A) coaxial LED light, network, active area: 102 mm x 100 mm, 24 VDC functions as an illumination component designed for machine vision and industrial inspection systems. These lighting devices provide uniform, direct, or coaxial light distribution to highlight surface defects, edges, or markings on inspected parts, ensuring reliable image capture by industrial cameras. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • 3-phase 3-wire mode: 200, 220, 230, 240 VAC
  • 3-phase 4-wire mode: 115, 127, 133, 138 VAC
  • 3-phase 3-wire mode: 380, 400, 415, 480 VAC
  • 3-phase 4-wire mode: 220, 230, 240, 277 VAC
  • Ambient operating temperature: -20 to 60°C (with no condensation or icing)
  • Storage temperature: -25 to 65°C (with no condensation or icing)
  • Altitude: 2,000 m max.
  • Input frequency: 50/60 Hz (AC power supply)
  • Output relays (1 × SPDT, normally closed operation): Resistive load
  • Maximum contact voltage: 250 VAC or 30 VDC
  • Maximum contact current: 5 A
  • Maximum switching capacity: 1,250 VA, 150 W
  • Mechanical life: 10,000,000 operations
  • Electrical life: 50,000 operations at 5 A, 250 VAC or 30 VDC
  • Degree of protection: Terminal section: IP20
  • Case material: PC and ABS

More info

▲
Features

3-phase asymmetry, phase-sequence, phase-loss relay

Monitors voltage asymmetry, phase sequence and phase loss for 3-phase 3-wire or 4-wire power supplies, in one unit.

  • Worldwide power specifications supported by one unit
  • Phase sequence, phase loss: operation reaction time 0.1s maximum
  • Asymmetry: operation time setting from 0.1 to 30s
  • Reset method: automatic
  • Power ON lock: 1s or 5s

Ordering information

Rated input

Order code

3-phase 3-wire mode

200, 220, 230, 240 VAC

K8AK-PA1

3-phase 4-wire mode

115, 127, 133, 138 VAC

3-phase 3-wire mode

380, 400, 415, 480 VAC

K8AK-PA2

3-phase 4-wire mode

220, 230, 240, 277 VAC

Specifications

Ambient operating temperature

-20 to 60°C (with no condensation or icing)

Storage temperature

-25 to 65°C (with no condensation or icing)

Altitude

2,000 m max.

Input frequency

50/60 Hz (AC power supply)

Output relays
(1 × SPDT, normally closed operation)

Resistive load

5 A at 250 VAC or at 30 VDC

Maximum contact voltage

250 VAC or 30 VDC

Maximum contact current

5 A

Maximum switching capacity

1,250 VA, 150 W

Mechanical life

10,000,000 operations

Electrical life

50,000 operations at 5 A, 250 VAC or 30 VDC

Degree of protection

Terminal section: IP20

Case material

PC and ABS

Weight

Approx. 130 g

Rated input voltage

K8AK-PA1

3-phase, 3-wire mode: 200, 220, 230, 240 VAC, 3-phase, 4-wire mode: 115, 127, 133, 138 VAC

K8AK-PA2

3-phase, 3-wire mode: 380, 400, 415, 480 VAC, 3-phase, 4-wire mode: 220, 230, 240, 277 VAC

Asymmetry operation (ASY.)

Operating value setting range

Asymmetry rate: 2% to 22%

Operating value

100% operation at set value

Asymmetry operating value = rated input voltage x asymmetry set value [%]

The asymmetry operation will function when the difference between the highest and lowest voltage phases equals or exceeds the asymmetry operating value

Reset (HYS.)

Hysteresis

5% of operating value (fixed)

Resetting method

Automatic reset

Operating time (T)

Asymmetry

0.1 s to 30 s

Phase-sequence, phase-loss

0.1 s max.

Power ON lock (LOCK)

1 s or 5 s (Changed with the DIP switch)

Overload capacity

Continuous input at 115% of maximum input, 10 s at 125% (up to 600 VAC)

Repeat accuracy

Operating value

±0.5% full scale (at 25°C and an ambient humidity of 65% at the rated power supply voltage, DC or 50/60 Hz sine wave input)

Operating time

±50 ms (at 25°C and 65% humidity, rated power supply voltage)

Indicators

Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM 1/2): Red LED

Applicable standards

Conforming standards

EN 60947-5-1
Installation environment (pollution level 2, installation category III)

EMC

EN 60947-5-1

Safety standards

UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA and CCC

Size in mm (H × W × D)

90 × 22.5 × 100


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.