View larger
LC-TH-51X51-VE AA051328C LCTH51X51VE OMRON Light control film for TH-51X51, vertical
LC-TH-51X51-VE
AA051328C
LCTH51X51VE
OMRON
1 Pcs.
Automation > Accessories/spare parts for sensor technology
Special
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Omron LC-TH-51X51-VE light control film for TH-51X51, vertical acts as a specialized optical filtering accessory used to manage illumination angles and reduce glare in industrial vision or sensing setups. Such films help optimize contrast and enhance target visibility during automated optical inspections.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 24 VAC/DC: Thermocouple or platinum resistance thermometer
- Transistor: Open collector: K8DT-TH1TD
- 100-240 VAC: Relay: SPDT contact output
- Transistor: Open collector: K8DT-TH1TA
- 24 VAC/DC: Thermocouple
- Transistor: Open collector: K8DT-TH2TD
- 100-240 VAC: Relay: SPDT contact output
- Transistor: Open collector: K8DT-TH2TA
- Power supply voltage: K8DT-TH__D: 24 VAC 50/60 Hz or 24 VDC K8DT-TH__A: 100 to 240 VAC 50/60 Hz
- Allowable voltage range: 85% to 110% of power supply voltage
- Power consumption: 24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max. 100 to 240 VAC: 3.1 VA max.
- Sensor inputs: Thermocouple: K, J, T, E
- Platinum-resistance thermometer: Pt100, Pt1000
- Setting method: Set of three rotary DIP switches
- Indicators: Power (PWR): Green, Alarm (ALM): Red
- Output form: Relay: SPDT contact output Transistor: Open collector
- Output relay ratings: Resistive load
More info
▲Temperature monitoring relay
Ideal to prevent heater overheating. Self-latching output to contribute to safe equipment operation.
- Set the temperature with ultra-simple rotary switches
- Digitally set the temperature to between 0 and 999°C in 1°C increments (K8DT-TH1__), or between 0 and 1,800°C in 10°C increments (K8DT-TH2__)
- Connect a thermocouple or platinum resistance thermometer
- Width of 17.5 mm to reduce space required in panels
- Push-in plus Technology that reduce wiring work
- UL listed for easy shipping to North America
- Double-insertion holes for crossover wiring (all terminals)
- Models added with transistor outputs for superior contact reliability
Ordering information
Power supply voltage | Input types | Setting units (setting range) | Output types | Order code |
|---|---|---|---|---|
24 VAC/DC | Thermocouple or platinum resistance thermometer | Setting unit: 1°C or 1°F | Relay: SPDT contact output | K8DT-TH1CD |
Transistor: Open collector | K8DT-TH1TD | |||
100-240 VAC | Relay: SPDT contact output | K8DT-TH1CA | ||
Transistor: Open collector | K8DT-TH1TA | |||
24 VAC/DC | Thermocouple | Setting unit: 10°C/°F | Relay: SPDT contact output | K8DT-TH2CD |
Transistor: Open collector | K8DT-TH2TD | |||
100-240 VAC | Relay: SPDT contact output | K8DT-TH2CA | ||
Transistor: Open collector | K8DT-TH2TA |
Accessories
Front Cover (Order separately)
Appearance | Order code |
|---|---|
Y92A-D1A |
Specifications
Item | K8DT-TH1 | K8DT-TH2 | |
|---|---|---|---|
Power supply voltage | K8DT-TH__D: 24 VAC 50/60 Hz or 24 VDC K8DT-TH__A: 100 to 240 VAC 50/60 Hz | ||
Allowable voltage range | 85% to 110% of power supply voltage | ||
Power consumption | 24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max. 100 to 240 VAC: 3.1 VA max. | ||
Sensor inputs | Thermocouple: K, J, T, E; | Thermocouple: K, J, T, E, B, R, S, PL II | |
Setting method | Set of three rotary DIP switches | ||
Indicators | Power (PWR): Green, Alarm (ALM): Red | ||
Output form | Relay: SPDT contact output Transistor: Open collector | ||
Output relay ratings | Resistive load | 5 A at 250 VAC | |
Inductive load | 1 A at 250 VAC | ||
Minimum load | 5 VDC, 10 mA (reference values) | ||
Mechanical life | 10 million operations min. | ||
Electrical life | 5 A at 250 VAC or 30 VDC: 50,000 operations | ||
Transistor output ratings | Contact form | SPST-NO (Open collector) | |
Rated voltage | 24 VDC (maximum voltage: 26.4 VDC) | ||
Maximum current | 50 mA DC | ||
Ambient operating temperature | −20 to 60°C (with no condensation or icing) | ||
Storage temperature | −25 to 65°C (with no condensation or icing) | ||
Case material | PC, UL 94 V-0 | ||
Weight | Approx. 100 g | ||
Size in mm (H × W × D) | 90×17.5×90 | ||
Measurement accuracy | ±1% of the setting range or ±4 °C, whichever is larger. | ±1% of the setting range (±1%FS). | |
Hysteresis width | 2°C | ||
Sampling cycle | 100 ms | ||
Applicable standards | Approved standards | EN 61010-1 Installation environment: Overvoltage category II, pollution level 2 | |
EMC | EN 61326-1 | ||
Safety standards | UL 61010-1 (Listing), Korean Radio Waves Act (Act 10564) | ||
Degree of protection | Terminals: IP20 | ||
1.Industrial Electromagnetic Environment (EN/IEC 61326-1, Table 2)