OMRON K8DT-VW2TA K8DT-VW2TA K8DT0035A K8DTVW2TA OMRON Single-phase Voltage Max and Min 1-150VAC/DC 100-240VAC 1 transistor 17.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

K8DT-VW2TA K8DT0035A K8DTVW2TA OMRON Single-phase Voltage Max and Min 1-150VAC/DC 100-240VAC 1 transistor 17..

K8DT-VW2TA

K8DT0035A

K8DTVW2TA

OMRON

1 Pcs.

Single-phase Voltage Max and Min 1-150VAC/DC 100-240VAC 1 transistor 17.5 mm Push-in+ Monitoring relay 17.5mm wide, Single phase over and under voltage 1 to 150 V AC /DC, 1 x Transistor, 100-240 VAC

Automation > Voltage monitoring relay
K8DT

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

FunctionsOver/under voltageInstallation typeDIN railTerminal typePush-inSize17.5 mmSetting range1 to 10 V AC/DC, 15 to 150 V AC/DC, 3 to 30 V AC/DCSupply voltage AC100-240 VOutput typeTransistorContact descriptionOpen collectorBody colorBlack
ETIM for 669454 Relays (EC001438)
Feature Name Feature Value
Type of electric connection (EF003961) Spring clamp connection
Voltage type (supply voltage) (EF002991) AC
Type of voltage measuring range (EF003399) AC/DC
Contains function DC-over voltage (EF003397) Yes
External power supply required (EF003292) Yes
Contains function DC-voltage hysteresis (EF003398) No
With detachable clamps (EF003340) No
Single-phase under voltage possible (EF003390) Yes
Three-phase under voltage possible (EF003391) No
Three-phase over voltage possible (EF003393) No
Contains function DC-under voltage (EF003396) Yes
Single-phase over voltage possible (EF003392) Yes
Single-phase hysteresis possible (EF003394) No
Three-phase hysteresis possible (EF003395) No
Number of contacts as change-over contact (EF008257) 1
Number of contacts as normally open contact (EF008256) 1
Min. adjustable delay-on energization time (EF008190) 0.1 s
Max. permitted delay-on energization time (EF008189) 30 s
Width (EF000008) 17.5 mm
Number of contacts as normally closed contact (EF008255) 0
Height (EF000040) 90 mm
Rated switch current (EF006706) 5 A
Depth (EF000049) 90 mm
Supply voltage AC 50 Hz (EF007532) 100 V
Response value voltage (EF008193) 1 V
Voltage measuring range 1 (EF006134) 1 V
Supply voltage AC 60 Hz (EF007533) 100 V

Product Datasheet