OMRON K8DT-AS3CD K8DT-AS3CD K8DT0009B K8DTAS3CD OMRON Single phase Current Max or Min 10-200 TO SPDT 24V AC/DC 17.5 mm Push-i.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

K8DT-AS3CD K8DT0009B K8DTAS3CD OMRON Single phase Current Max or Min 10-200 TO SPDT 24V AC/DC 17.5 mm Push-i..

K8DT-AS3CD

K8DT0009B

K8DTAS3CD

OMRON

1 Pcs.

Single phase Current Max or Min 10-200 TO SPDT 24V AC/DC 17.5 mm Push-in+ Monitoring relay 17.5mm wide, Single phase over or under current 10 to 200 A AC /DC, 1 x SPDT, 24 V AC/DC

Automation > Current monitoring relay
K8DT

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Omron single-phase current monitoring relay (K8DT-AS3CD) provides precise electrical supervision in industrial control environments, designed to spot hazardous load fluctuations and safeguard valuable plant machinery. Plant engineers integrate these units to trigger prompt protective shutdowns or alarms whenever monitored currents exceed or fall below preset thresholds. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of electric connection (EF003961): Spring clamp connection
  • Voltage type (supply voltage) (EF002991): AC/DC
  • Three-phase under current possible (EF003406): No
  • Function DC-current hysteresis (EF003411): No
  • Single-phase under current possible (EF003405): Yes
  • External power supply required (EF003292): Yes
  • Contains function DC-voltage overcurrent (EF003410): No
  • With detachable clamps (EF003340): Yes
  • External current transformer (EF001923): Yes
  • Single-phase overcurrent possible (EF003407): Yes
  • Three-phase overcurrent possible (EF003408): No
  • Contains function DC-voltage under current (EF003409): No
  • Single-phase hysteresis possible (EF003394): Yes
  • Three-phase hysteresis possible (EF003395): No
  • Number of contacts as change-over contact (EF008257): 1
  • Number of contacts as normally open contact (EF008256): 0

More info

▲
FunctionsCurrentInstallation typeDIN railTerminal typePush-inSize17.5 mmSetting range10 to 100 A AC, 20 to 200 A ACSupply voltage AC20.4-26.4 VSupply voltage DC20.4-26.4 VOutput typeRelayContact descriptionSPDTBody colorBlackExternal current transformer

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.