View larger
H3DT-HCL 100-120VAC H3DT0013C H3DTHCLAC100120V OMRON 17.5 mm DIN-Delay OFF 1s-120s 100-120 Vac Push-in+
H3DT-HCL 100-120VAC
H3DT0013C
H3DTHCLAC100120V
OMRON
1 Pcs.
Automation > Timer relay
H3DT
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for space-saving DIN rail layouts, the Omron H3DT-HCL 100-120VAC timer relay provides precision OFF-delay management for industrial automation architectures. Technicians use these modules to maintain auxiliary power or control signals for specific durations after system shutdown commands are given.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Multi-range, multi-mode standard timer: 24 to 240 VAC/DC
- 8 terminals: Relay, SPDT
- 8 terminals: Relay, SPDT
- Power ON-delay timer: 24 to 240 VAC/DC
- 6 terminals: Relay, SPDT
- Twin timer: 24 to 240 VAC/DC
- Star-delta timer: 24 to 240 VAC/DC
- Power OFF-delay Timer: 100 to 120 VAC
- 200 to 240 VAC: H3DT-HDS
- 24 to 48 VAC/DC: H3DT-HBS
- 100 to 120 VAC: 1 to 120 s
- 200 to 240 VAC: H3DT-HDL
- 24 to 48 VAC/DC: H3DT-HBL
- Power supply voltage: 24 to 240 VAC/DC, 50/60 Hz 5 , 6
- Allowable voltage fluctuation range: 85% to 110% of rated voltage
- Power reset: Minimum power-OFF time: 0.1 s
More info
▲DIN 17.5-mm-wide slim timers with Push-in plus Technology for in-panel applications
- Helps save space and reduces work in control panels
- Slim timers (17.5-mm width) with two sets of contacts: One of the slimmest timers worldwide
- Reduces power consumption (active power) by up to 60% to help reduce heat generation in control panels
- Certified for maritime standards (LR/DNV GL)
- RoHS compliant
Ordering information
| B3: Flicker OFF Start (Power ON Start) | |||||||
| B: Flicker OFF Start (Signal Start) B2: Flicker ON Start (Signal Start) | |||||||
1 to 120 s4 | |||||||
Specifications
24 to 48 VAC/DC, 50/60 Hz2 | |||||||||||
24 to 240 VAC/DC | |||||||||||
At 240 VAC: 2.3 VA max., | At 240 VAC: 2.0 VA max., | At 240 VAC: 2.2 VA max., | At 240 VAC: 1.8 VA max., at 24 VDC: 0.3 W max.3 | At 240 VAC: 1.9 VA max., | |||||||
The minimum applicable load is 10 mA at 5 VDC (P reference value). | |||||||||||
| Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | |||||||||||