OMRON GX-JC06-H GX-JC06-H GX 5032D GXJC06H OMRON Module connections EtherCAT 6 ports, power supply of 24 Vdc View larger
Images are for illustrative purposes only. Please refer to data sheet for details

GX-JC06-H GX 5032D GXJC06H OMRON Module connections EtherCAT 6 ports, power supply of 24 Vdc

GX-JC06-H

GX 5032D

GXJC06H

OMRON

1 Pcs.

Module connections EtherCAT 6 ports, power supply of 24 Vdc 6-port EtherCAT Junction module, 24 VDC power supply, with node switches

Automation > Network switch
Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The GX-JC06-H GX 5032D GXJC06H OMRON Module connections EtherCAT 6 ports, power supply of 24 Vdc produced by Omron functions as a decentralized I/O and communication building block designed to link field devices within industrial bus networks. Modular I/O units collect signals from sensors and transmit commands to actuators efficiently across machine architectures.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • 16-point NPN input unit: 24 VDC, 6 mA per point
  • 16-point NPN input unit: 24 VDC, 6 mA per point
  • 16-point PNP input unit: 24 VDC, 6 mA per point
  • 16-point PNP input unit: 24 VDC, 6 mA per point
  • 16-point relay output unit: 2 A per point, max. 8 A per common
  • 16-point NPN output unit: 24 VDC, 0.5 A per point
  • 16-point NPN output unit: 24 VDC, 0.5 A per point
  • 16-point PNP output unit: 24 VDC, 0.5 A per point
  • 16-point PNP output unit: 24 VDC, 0.5 A per point
  • 8-point input + 8-point output unit (NPN): 24 VDC, input 6 mA, output 0.5 A per point
  • 8-point input + 8-point output unit (NPN): 24 VDC, input 6 mA, output 0.5 A per point
  • 8-point input + 8-point output unit (PNP): 24 VDC, input 6 mA, output 0.5 A per point
  • 8-point input + 8-point output unit (PNP): 24 VDC, input 6 mA, output 0.5 A per point
  • 4-Channel analog input unit: 1 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA,
  • 2-Channel analog output unit: 1 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA,
  • 1-Channel incremental encoder input (24V): Open collector, up to 125 kHz

More info

▲
Features

When speed counts: EtherCAT I/O

EtherCAT is an extremely fast industrial automation network, which uses standard Ethernet cabling. It makes very efficient use of the standard Ethernet transmission frame, with each node accessing the entire frame on the fly. This reduces the delay in each slave to microsecond level. Its deterministic nature makes EtherCAT extremely suitable for motion control. Omron provides PLC-based as well as stand-alone motion control solutions based on EtherCAT. The GX-series I/O units provide the basic in- and outputs for such systems, including high-speed encoder inputs which can feed position information into the controller.

  • Compact size IP20 housing
  • Expandable digital I/Os
  • Detachable I/O terminal blocks
  • Selectable high-speed input response time

Ordering information

Unit Type

Specification

Size in mm (H×W×D)

Remarks

Order code

16-point NPN input unit

24 VDC, 6 mA per point

52×135×57

Expandable with one XWT unit

GX-ID1611

16-point NPN input unit

24 VDC, 6 mA per point

52×200×69

3-tier connection for direct sensor wiring

GX-ID1612

16-point PNP input unit

24 VDC, 6 mA per point

52×135×57

Expandable with one XWT unit

GX-ID1621

16-point PNP input unit

24 VDC, 6 mA per point

52×200×69

3-tier connection for direct sensor wiring

GX-ID1622

16-point relay output unit

2 A per point, max. 8 A per common

52×160×58

with easy-to-replace relays, expandable with one XWT unit

GX-OC1601

16-point NPN output unit

24 VDC, 0.5 A per point

52×135×57

Expandable with one XWT unit

GX-OD1611

16-point NPN output unit

24 VDC, 0.5 A per point

52×200×69

3-tier connection for direct sensor wiring

GX-OD1612

16-point PNP output unit

24 VDC, 0.5 A per point

52×135×57

Expandable with one XWT unit

GX-OD1621

16-point PNP output unit

24 VDC, 0.5 A per point

52×200×69

3-tier connection for direct sensor wiring

GX-OD1622

8-point input + 8-point output unit (NPN)

24 VDC, input 6 mA, output 0.5 A per point

52×135×57

-

GX-MD1611

8-point input + 8-point output unit (NPN)

24 VDC, input 6 mA, output 0.5 A per point

52×200×69

3-tier connection for direct sensor wiring

GX-MD1612

8-point input + 8-point output unit (PNP)

24 VDC, input 6 mA, output 0.5 A per point

52×135×57

-

GX-MD1621

8-point input + 8-point output unit (PNP)

24 VDC, input 6 mA, output 0.5 A per point

52×200×69

3-tier connection for direct sensor wiring

GX-MD1622

4-Channel analog input unit

1 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA,

52×135×57

Resolution 1/6000, conversion time 4 ms (4 inputs)

GX-AD0471

2-Channel analog output unit

1 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA,

52×135×57

Resolution 1/6000, conversion time 2 ms (2 outputs)

GX-DA0271

1-Channel incremental encoder input (24V)

Open collector, up to 125 kHz

52×215×69

A, B, Z, 2 × Latch, Reset inputs

GX-EC0211

1-Channel incremental encoder input (line driver)

RS422 signal level, up to 1 MHz

52×215×69

A, B, Z, 2 × Latch, Reset inputs

GX-EC0241

Expansion units

Unit Type

Specification

Size in mm (H×W×D)

Remarks

Order code

8-point PNP input expansion unit

24 VDC, 6 mA per point

50×66×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-ID08-1

16-point PNP input expansion unit

24 VDC, 6 mA per point

50×94×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-ID16-1

8-point PNP output expansion unit

24 VDC, 0.5 A per point

50×66×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-OD08-1

16-point PNP output expansion unit

24 VDC, 0.5 A per point

50×94×50

Expansion unit for GX, DRT2 and CRT1 series

XWT-OD16-1

3 port branching uni

24 VDC, 3 x RJ45

90×25×78

EtherCAT junction box for T-branching

GX-JC03

6 port branching unit

24VDC, 6 x RJ45

90×48×78

EtherCAT junction box for star branching

GX-JC06

Note:To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the “-1” from the model code.