View larger
G9SX-GS226-T15-RC DC24 G9SX6021M G9SXGS226T15RCDC24,1 OMRON Security module with 2 modes of operation, termi..
G9SX-GS226-T15-RC DC24
G9SX6021M
G9SXGS226T15RCDC24.1
OMRON
1 Pcs.
Automation > Device for monitoring of safety-related circuits
G9SX
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Security module with 2 modes of operation, termi.. by Omron (G9SX-GS226-T15-RC DC24, part number G9SX6021M) is utilized in manufacturing plants to manage safety door interlocks and operational mode selections. This module ensures that machinery operates securely under specific guarding conditions to prevent operator injury. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Two contacts: 1NC (grip output)
- 2 (Semi- conductors): 2 (Semi- conductors)
- Spring-cage terminals: G9SX-GS226-T15-RC
- Rated supply voltage: 24 VDC
- Safety input: Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ
- Auxiliary output: PNP transistor output Load current: 100 mA max.
More info
▲Safety guard switching unit
The safety controller to support maintenance mode and normal operation mode in a safe way.
- Two operation modes to support auto switching for applications where machine an worker co-operate and manual switching for applications with limitaions in operation like maintenance
- Clear LED diagnosis of all in- and outputs
- Applicable up to Category 4 acc. EN 954-1
Enabling grip switches
Safety guard switching units
Safety outputs1 | Auxiliary outputs2 | Max. OFF | ||||||
|---|---|---|---|---|---|---|---|---|
OFF-delayed4 | ||||||||
Specifications
Ratings of guard switching unit
Power input
Inputs
Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ | |
Outputs
Application example
Automatic switching mode
Worker is loading and unloading the machine manually. When loading is finished, robot cycle is started manually by the worker. When robots return to their home position, loading cycle is selected automatically.
Loading condition: Safety sensor B is not active, safety sensor A is active because the robots are not allowed to move to the loading area while the worker loads the machine. So the worker is safe because safety sensor A is active.
Robot work condition: Safety sensor B is active, safety sensor A is not active because the worker is not allowed to move to the loading area when the robots work. So the worker is safe because safety sensor B stops the machine if he moves to the loading area.

Manual switching mode
Worker has to do maintenance in this machine. While maintenance, it is necessary to move the machine in a limited way. The worker has to select automatic mode or manual mode manually by using the mode selector switch.
Operation steps:
1)Select maintenance mode by using the mode selector
2)Open the door to do the maintenance while the machine still is able to operate in a limited way (monitoring of limited movement by using the safety limit switch).
3)Close the cover after finishing maintenance
4)Select automatic mode by using the mode selector
E-Stop conditions:
a)open the door while not in maintenance mode
b)the machine actuates the limit switch (breaks the limit).
c)the Enabling grip switch A4EG is actuated to stop the machine in emergency condition.