View larger
G9SR-EX031-T90-RC AA041678D G9SREX031T90RC OMRON Module Expansion to G9SR-AD 3PST-NA 5A 22.5 mm 24vdc
G9SR-EX031-T90-RC
AA041678D
G9SREX031T90RC
OMRON
1 Pcs.
Automation > Device for monitoring of safety-related circuits
G9SR
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
G9SR-EX031-T90-RC AA041678D G9SREX031T90RC OMRON Module Expansion to G9SR-AD 3PST-NA 5A 22.5 mm 24vdc operates as an expansion module designed to scale up safety relay systems by adding extra contact outputs to a base controller. These extension units are commonly integrated into factory automation networks to expand monitoring zones and safely interrupt multiple actuator circuits simultaneously. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- 2 PST-NO (contact): 1 PNP transistor output
- 2 P channel MOS FET transistor output: 1 PNP transistor output
- -: 3 PST-NO (contact) 1
- Rated supply voltage: 19.2 to 28.8 VDC (24 VDC ±20%)
- Safety input: Operating voltage: 17 VDC to 28.8 VDC, internal impedance: Approx. 3 kΩ
- Auxiliary output: PNP transistor output Load current: 500 mA max.
- Operating time (OFF to ON): 150 ms max.
- Response time (ON to OFF): 50 ms max.
- Durability: Electrical
- Ambient temperature: -10 to 55°C (with no icing or condensation)
More info
▲Compact safety relay unit family
G9SR family modules operate standalone and as a system with input and output extension. All modules are simple to set up using DIP-switches and provide clear diagnosis via LEDs on the front.
- Three modules for all safety relay unit applications
- Solid-state outputs for long life and high current safety relay outputs
- Detailed LED indications enable easy diagnosis
- Safe on- and off-delay function up to PLe
- Up to PLe according to EN ISO 13949-1 and SIL 3 according to EN 61508
Ordering information
Advanced unit
Basic unit
Expansion unit
3 PST-NO (contact)1 | |||||
Specifications
Power input
Inputs
Operating voltage: 17 VDC to 28.8 VDC, | |||