G9SE-221-T30 DC24 G9SE9004G G9SE221T30DC24FOROEE OMRON Safety relay, 24 V DC, 4 outputs up to 5 A max. (2+2 ..
G9SE-221-T30 DC24
G9SE9004G
G9SE221T30DC24FOROEE
OMRON
1 Pcs.
Automation > Device for monitoring of safety-related circuits
G9SE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Omron safety relay G9SE-221-T30 DC24 (part number G9SE9004G) manages off-delayed safety outputs to ensure orderly shutdown sequences in automated industrial processes. Such relays coordinate emergency stop signals across multi-zone manufacturing lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 4PST-NO: G9SE-401
- DPST-NO: DPST-NO
- DPST-NO: DPST-NO
- Rated supply voltage: 24 VDC
- Operating voltage range: -15% to 10% of rated supply voltage
- Rated power consumption 3: 3 W max.
- Safety output OFF-delayed safety output: Contact output 250 VAC 5 A 30 VDC 5 A (resistance load)
- Auxiliary output: PNP transistor output Load current: 100 mA DC max.
- Operating time (OFF to ON state) 4: 100 ms Max. 5
- Response time (ON to OFF state) 6: 15 ms Max.
- Inputs: Input current
- ON voltage: 11 VDC Min.
- OFF voltage: 5 VDC Max.
- OFF current: 1 mA Max.
- Maximum cable length: 100 m Max.
- Reset input time: 250 ms Min.
More info
▲Slim-size safety relay unit family
G9SE-family offers compact units for E-Stop, door and safety monitoring applications . Modules with two or four safety contacts and OFF-delay timing are available on slim-size housing.
- Simple front side wiring using screw-less terminals.
- 17.5 or 22.5 mm width to save mounting space
- 15ms Max. response time
- Safe OFF delay function up to PLe
- Certification for lift standards EN 81-1, EN 81-2
- Up to Ple according to EN ISO 13849-1 and SIL 3 according to EN 61508
Ordering information
Auxiliary outputs1 | Max. OFF-delay time2 | ||||
|---|---|---|---|---|---|
Specifications
Ratings
Power Input
Rated power consumption3 | |||
Outputs
Characteristics
Operating time (OFF to ON state)4 | 100 ms Max.5 | ||||
Response time (ON to OFF state)6 | |||||
Contact resistance7 | |||||
100A8 | |||||
2.The OFF-delay time can be set in 16 steps as follows:
T05: 0/0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/1/1.5/2/2.5/3/4/5 s
T30: 0/1/2/4/5/6/7/8/9/10/12/14/16/20/25/30 s
4.The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not including bounce time.
5.This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..