View larger
G9SE-221-T05 DC24 G9SE9003R G9SE221T05DC24FOROEE OMRON Safety relay, 24 V DC, 4 outputs up to 5 A max. (2+2 ..
G9SE-221-T05 DC24
G9SE9003R
G9SE221T05DC24FOROEE
OMRON
1 Pcs.
Automation > Device for monitoring of safety-related circuits
G9SE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Omron G9SE-221-T05 DC24 safety relay, 24 V DC, 4 outputs up to 5 A max. (2+2 acts as a dedicated logic solver for monitoring emergency circuits and safeguarding moving machine parts. It processes signals from protective devices and drops out safely to prevent unexpected hazardous motion in industrial settings. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 4PST-NO: G9SE-401
- DPST-NO: DPST-NO: DPST-NO: DPST-NO
- Rated supply voltage: 24 VDC
- Operating voltage range: -15% to 10% of rated supply voltage
- Rated power consumption 3: 3 W max.
- Safety output OFF-delayed safety output: Contact output 250 VAC 5 A 30 VDC 5 A (resistance load)
- Auxiliary output: PNP transistor output Load current: 100 mA DC max.
- Operating time (OFF to ON state) 4: 100 ms Max. 5
- Response time (ON to OFF state) 6: 15 ms Max.
- Inputs: Input current
- ON voltage: 11 VDC Min.
- OFF voltage: 5 VDC Max.
- OFF current: 1 mA Max.
- Maximum cable length: 100 m Max.
- Reset input time: 250 ms Min.
More info
▲Slim-size safety relay unit family
G9SE-family offers compact units for E-Stop, door and safety monitoring applications . Modules with two or four safety contacts and OFF-delay timing are available on slim-size housing.
- Simple front side wiring using screw-less terminals.
- 17.5 or 22.5 mm width to save mounting space
- 15ms Max. response time
- Safe OFF delay function up to PLe
- Certification for lift standards EN 81-1, EN 81-2
- Up to Ple according to EN ISO 13849-1 and SIL 3 according to EN 61508
Ordering information
Auxiliary outputs1 | Max. OFF-delay time2 | ||||
|---|---|---|---|---|---|
Specifications
Ratings
Power Input
Rated power consumption3 | |||
Outputs
Characteristics
Operating time (OFF to ON state)4 | 100 ms Max.5 | ||||
Response time (ON to OFF state)6 | |||||
Contact resistance7 | |||||
100A8 | |||||
2.The OFF-delay time can be set in 16 steps as follows:
T05: 0/0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/1/1.5/2/2.5/3/4/5 s
T30: 0/1/2/4/5/6/7/8/9/10/12/14/16/20/25/30 s
4.The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not including bounce time.
5.This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max..