OMRON G32X-V2K G32X-V2K G32 1032G G32XV2K OMRON Potentiometer 2K Ohm G3PX View larger
Images are for illustrative purposes only. Please refer to data sheet for details

G32X-V2K G32 1032G G32XV2K OMRON Potentiometer 2K Ohm G3PX

G32X-V2K

G32 1032G

G32XV2K

OMRON

1 Pcs.

Potentiometer 2K Ohm G3PX External variable resistor, 2 kW, for G3PW power controller

Automation > Accessories/spare parts for switching relay
Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Omron G32X-V2K (G32 1032G) is a potentiometer 2K Ohm G3PX configured for precise analog control within power controller setups. External variable resistors allow operators to fine-tune output parameters, phase angles, or cycle configurations in industrial heating and motor systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • 100 to 240 VAC: 20 A
  • 45 A: G3PW-A245EU-C
  • 60 A: G3PW-A260EU-C
  • 20 A: Constant current
  • 45 A: G3PW-A245EC-C-FLK
  • 60 A: G3PW-A260EC-C-FLK
  • 20 A: Standard
  • 45 A: G3PW-A245EU-S
  • 60 A: G3PW-A260EU-S
  • 20 A: Constant current
  • 45 A: G3PW-A245EC-S-FLK
  • 60 A: G3PW-A260EC-S-FLK
  • External Variable Resistor: 2 kΩ
  • Control method: Analog input: Phase control or optimum cycle control Voltage ON/OFF input: ON/OFF control
  • Optimum cycle control: Optimum cycle control (Output is switched to 100% or 0% each half cycle.)
  • Voltage ON/OFF input: ON/OFF control

More info

▲
  • Precise heater burnout detection
  • Phase control or optimum cycle control
  • RS-485 communications to set manipulated variables and monitor load current
  • Total runtime monitoring
  • Application with various loads: constant load resistance, variable load resistance

Specifications & ordering info

Ordering information

Applicable output load

Type

Contact terminal block

Heater burnout detection

Communications

Order code

100 to 240 VAC

20 A

Standard

Screwless clamp terminal block

No

No

G3PW-A220EU-C

45 A

G3PW-A245EU-C

60 A

G3PW-A260EU-C

20 A

Constant current

Yes

Yes

G3PW-A220EC-C-FLK

45 A

G3PW-A245EC-C-FLK

60 A

G3PW-A260EC-C-FLK

20 A

Standard

Terminal block with small slotted screws

No

No

G3PW-A220EU-S

45 A

G3PW-A245EU-S

60 A

G3PW-A260EU-S

20 A

Constant current

Yes

Yes

G3PW-A220EC-S-FLK

45 A

G3PW-A245EC-S-FLK

60 A

G3PW-A260EC-S-FLK

Accessories (Order separately)

Name

Resistive value

Display

Order code

External Variable Resistor

2 kΩ

202

G32X-V2K

Specifications

Order code

Standard Models

Constant-current Models

G3PW-A2__EU-_

G3PW-A2__EC-__-FLK

Control method

Analog input: Phase control or optimum cycle control

Voltage ON/OFF input: ON/OFF control

Maximum load capacity

Phase control: Linear (resistive) load, transformer primary-side control (flux density: 1.25 T max.)

Optimum cycle control: Linear (resistive) load (Transformer primaryside control is not supported.)

Output mode

Analog input

Phase control

Proportional to phase angle (same as G3PX), proportional to square voltage, proportional to voltage

Proportional to phase angle (same as G3PX), proportional to square voltage, proportional to voltage, constant-current control

Optimum cycle control

Optimum cycle control (Output is switched to 100% or 0% each half cycle.)

Voltage ON/OFF input

ON/OFF control

Proportional to voltage control


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.