View larger
E2E-X3B4-IL2 5M E2E 8278D E2EX3B4IL25MOMS OMRON Inductive Short-3h Enr 3mm M12 PNP no/NC Cable 5m IO LINK CO..
E2E-X3B4-IL2 5M
E2E 8278D
E2EX3B4IL25MOMS
OMRON
1 Pcs.
Automation > Inductive proximity switch
E2E
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Omron E2E-X3B4-IL2 5M inductive sensor offers precise non-contact detection of metal objects within manufacturing machinery, material handling systems, and automated production cells. These devices help control cycles, verify component positioning, and feed operational data back to programmable logic controllers.
Exact pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- COM3: E2E-X3B4-IL3 2M
- M12 Pre-wired Smartclick connector models (0.3 m): 1: +V 3: 0 V 4: C/Q output
- COM3: E2E-X3B4-M1TJ-IL3 0.3M
- M18: 7 mm
- COM3: E2E-X7B4-IL3 2M
- M12 Pre-wired Smartclick connector models (0.3 m): 1: +V 3: 0 V 4: C/Q output
- COM3: E2E-X7B4-M1TJ-IL3 0.3M
- M30: 10 mm
- COM3: E2E-X10B4-IL3 2M
- M12 Pre-wired Smartclick connector models (0.3 m): 1: +V 3: 0 V 4: C/Q output
- COM3: E2E-X10B4-M1TJ-IL3 0.3M
- Sensing distance: 3 mm ±10%
- Set distance 1: 0 to 2.4 mm
- Differential travel: 10% max. of sensing distance
- Response frequency 2: 1 kHz
- Power supply voltage: 10 to 30 VDC (including 10% ripple (p-p))
More info
▲IO-Link standard proximity sensors as the innovative solution to solve issues at industrial manufacturing sites
IO-Link standard proximity sensors as the innovative solution to solve issues at industrial manufacturing sites
- Downtime can be reduced through internal diagnostic functions
- The sudden failure can be decreased by notifying, if objects being too far or too close
- Maintenance operations are more efficient by identification of each sensor through the IO link network
- Programmable operation of the sensor reduces the number of models required
DC 3-wire IO-Link models
![]() | ||||||||
Specifications
DC 3-wire IO-Link models (E2E-X_B4-IL_)
Set distance1 | ||||
Response frequency2 | ||||
Indicators1 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and stability indicator (green, lit) In the IO-Link mode: Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | |||
IEC 60529 IP67, in-house standards: oil-resistant3 | ||||
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) | ||||
Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, and initial reset | ||||
PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||

In the IO-Link mode, use the product in a range that the Byte1_bit4 for instability detection is zero. (Although the Byte1_bit5 for excessive proximity detection is one if the object detected has approached excessively, the detection performance is stable.)
Please contact your OMRON sales representative regarding assignment of data.