OMRON K35-1 K35-1 K35 1001A K351 OMRON Card. K3HB-Entry Event 5 NPN View larger
Images are for illustrative purposes only. Please refer to data sheet for details

K35-1 K35 1001A K351 OMRON Card. K3HB-Entry Event 5 NPN

K35-1

K35 1001A

K351

OMRON

1 Pcs.

Card. K3HB-Entry Event 5 NPN option board (Slot D), not compatible with K3N models, NPN open collecor event input card 5 points M3 terminal block

Automation > Accessories/spare parts for measuring instruments for installation
Other

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Omron K35-1 card. K3HB-entry event 5 NPN serves as an option module for digital panel meters, providing signal processing capabilities for discrete event inputs. Event cards allow measurement instruments to interface effectively with various industrial switches, sensors, and control architectures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Accessory (EF013236): Yes
  • Spare part (EF013237): No

More info

K3HB-C, -P, -R 1/8 DIN advanced indicators
Rotary pulse, timer interval and up/down counting pulse indicators
These indicators with analog input feature a clear and easy-to-use color change dis- play. All models are equipped with an IP66 housing. K3HB-R and -C are high-speed, with a sample rate up to 50 kHz.
• Position meter indication for easy monitoring
• Optional DeviceNet, RS-232C, RS-485
• Double display, with 5 digits, in two colors
• 1/8 DIN size housing
Ordering information
Type of indicator Input ranges Supply voltage Input sensor Order code
Rotary pulse indicator K3HB-R No voltage contact: 30 Hz max. 100 to 240 VAC NPN input/voltage pulse K3HB-RNB 100-240VAC
Voltage pulse: 50 kHz max. Open collector: 50 kHz max.
24 VAC/VDC K3HB-RNB 24VAC/VDC
100 to 240 VAC PNP input K3HB-RPB 100-240VAC
24 VAC/VDC K3HB-RPB 24VAC/VDC
100 to 240 VAC NPN K3HB-PNB 100-240VAC
100 to 240 VAC PNP K3HB-PPB 100-240VAC
Timer interval indicator K3HB-P 24 VAC/VDC PNP K3HB-PPB 24VAC/VDC
100 to 240 VAC NPN K3HB-CNB 100-240VAC Up/down counting pulse indicator K3HB-C 24 VAC/VDC NPN K3HB-CNB 24VAC/VDC
24 VAC/VDC PNP K3HB-CPB 24VAC/VDC
Option boards
Sensor power supply/output boards
Slot Output Sensor power supply Communications Order code
B Relay PASS: SPDT 12 VDC ±10%, 80 mA – K33-CPA *1
Linear current DC0(4) - 20 mA – K33-L1 A *2
Linear voltage DC0(1) - 5 V, 0 to 10 V – K33-L2A *2
– – – K33-A *2
– – RS-232C K33-FLK1 A *2
– – RS-485 K33-FLK3A *2
Relay/transistor output boards
Slot Output Communications Order code
C Relay H/L: SPDT each – K34-C1
HH/H/LL/L: SPST-NO each – K34-C2
Transistor NPN open collector: HH/H/PASS/L/LL – K34-T1
PNP open collector: HH/H/PASS/L/LL – K34-T2
– DeviceNet K34-DRT *2
BCD + transistor NPN open collector: HH/H/PASS/L/LL – K34-BCD
Event input boards
Slot Input type Number of points Communications Order code
D NPN open collector 5 M3 terminal blocks K35-1
8 10-pin MIL connector K35-2
PNP open collector 5 M3 terminal blocks K35-3
8 10-pin MIL connector K35-4
*1 CPA can be combined with relay outputs only.
*2 Only one of the following can be used by each digital indicator: RS-232C/RS-485 communications, a linear output, or DeviceNet communications.
K3HB has got three slots for option boards: Slot B, slot C and slot D.
Accessories
Type Order code Special cable (for event inputs with 8-pin connector) K32-DICN Special BCD output cable K32-BCD
590
K3HB-C, -P, -R 1/8 DIN advanced indicators
Specifications
Power supply voltage 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC
Allowable power supply voltage range 85 to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
Power consumption 100 to 240 V: 18 VA max. (max. load), 24 VAC/DC: 11 VA/7 W max. (max. load)
Display method Negative LCD (backlit LED) display 7-segment digital display
(character height: PV: 14.2 mm (green/red) SV: 4.9 mm (green))
Ambient operating temperature –10 to 55°C (with no icing or condensation)
Display range –19,999 to 99,999
Weight Approx. 300 g (base unit only)
Degree of protection Front-panel Conforms to NEMA 4X for indoor use (equivalent to IP66)
Rear case IP20
Terminals IP00 + finger protection (VDE0106/100)
Memory protection EEPROM (non-volatile memory), number of rewrites: 100,000
Event input ratings Contact ON: 1 k max., OFF: 100 k min.
No-contact ON residual voltage: 2 V max., OFF leakage current: 0.1 mA max., load current: 4 mA max.
Maximum applied voltage: 30 VDC max.
Output ratings Transistor output Maximum load voltage 24 VDC Maximum load current 50 mA Leakage current 100 μA max.
Contact output
(resistive load)
Rated load 5 A at 250 VAC, 5 A at 30 VDC
Rated through current 5 A
Mechanical life expectancy 5,000,000 operations
Electrical life expectancy 100,000 operations
Linear output Allowable load impedance 500  max. (mA) 5 k min. (V)
Resolution Approx. 10,000
Output error ±0.5% FS
Size in mm (H×W×D) 48×96×100
591


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.