OMRON K32-49HC K32-49HC K32 1001M K3249HC OMRON Front cover plastic K3N / K3T View larger
Images are for illustrative purposes only. Please refer to data sheet for details

K32-49HC K32 1001M K3249HC OMRON Front cover plastic K3N / K3T

K32-49HC

K32 1001M

K3249HC

OMRON

1 Pcs.

Front cover plastic K3N / K3T Hard cover for use with 96x48mm panel meter

Automation > Accessories/spare parts for measuring instruments for installation
Other

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Features

Highly visible LCD display with 2-colour (red and green) LEDs

The K3MA-F is a frequency/rate meter with a supply voltage of either 100 to 240VAC or 24VAC/VDC. Both are equipped with the same quality display and have the same short depth of 80mm.

  • DIN-size of H 48 x W 96mm
  • Highly visible, negative transmissive back-lit LCD display
  • 14.2mm-high characters
  • 5 digits (-19999 to 99999)
  • Front-panel IP66

Ordering information

Indicator

Supply voltage

Input type & ranges

Output

Order code

Process meter

100 to 240 VAC

DC voltage: 0 to 5 V, 1 to 5 V, -5 to 5 V, -10 to 10 V

DC current: 0 to 20 mA, 4 to 20 mA

2 relay contact outputs (SPST-NO)

K3MA-J-A2 100-240VAC

24 VAC/VDC

2 relay contact outputs (SPST-NO)

K3MA-J-A2 24VAC/VDC

Temperature meter

100 to 240 VAC

Platinum-resistance thermometer: Pt100, JPt100
or thermocouple K, J, T, E, L, U, N, R, S, B

1 relay contact output (SPDT)

K3MA-L-C 100-240VAC

24 VAC/VDC

1 relay contact output (SPDT)

K3MA-L-C 24VAC/VDC

Frequency/rate meter

100 to 240 VAC

Rotary pulse: No voltage: 0.05 to 30.00 Hz;

open collector: 0.1 to 5000.0 Hz

2 relay contact outputs (SPST-NO)

K3MA-F-A2 100-240VAC

24 VAC/VDC

2 relay contact outputs (SPST-NO)

K3MA-F-A2 24VAC/VDC

Accessories

Type

Order code

Splash-proof soft cover

K32-49SC

Hard cover

K32-49HC

Specifications

Item

100-240 VAC models

24 VAC/VDC models

Supply voltage

100 to 240 VAC

24 VAC (50/60 Hz), 24 VDC

Operating voltage range

85 to 110% of the rated supply voltage

Power consumption (under maximum load)

6 VA max.

4.5 VA max. (24 VAC) 4.5 W max. (24 VDC)

Ambient temperature

Operating: -10 to 55°C (with no condensation or icing)

Storage: -25 to 65°C (with no condensation or icing)

Weight

Approx. 200 g

Display

7-segment digital display, character height: 14.2 mm

Polarity display

“-” is displayed automatically with a negative input signal

Zero display

Leading zeros are not displayed

Hold function

Max. hold (maximum value), min. hold (minimum value)

Hysteresis setting

Programmable with front-panel key inputs (0001 to 9,999)

Delay in comparative outputs

1 s max.

Degree of protection

Front-panel: NEMA4X for indoor use (equivalent to IP66)
Rear case: IEC standard IP20
Terminals: IEC standard IP00 + finger protection (VDE 0106/100)

Memory protection

Non-volatile memory (EEPROM) (possible to rewrite 100,000 times)

Size in mm (H×W×D)

48×96×80


ETIM for 118244 Modular devices for distribution board/surface mounting (EC002295)
Feature Name Feature Value
Type of accessory/spare part (EF000215) Other
Accessory (EF013236) Yes
Spare part (EF013237) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.