OMRON CP1E-E10DT1-A CP1E-E10DT1-A CP1W0120A CP1EE10DT1A OMRON CPU 6/4 I/O AC Outputs Transistor PNP 2K Program, 2K Data View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CP1E-E10DT1-A CP1W0120A CP1EE10DT1A OMRON CPU 6/4 I/O AC Outputs Transistor PNP 2K Program, 2K Data

CP1E-E10DT1-A

CP1W0120A

CP1EE10DT1A

OMRON

1 Pcs.

CPU 6/4 I/O AC Outputs Transistor PNP 2K Program, 2K Data PLC, 100-240 VAC supply, 6 x 24 VDC inputs, 4 x PNP outputs 0.3 A, 2K steps program + 2K words data memory

Automation > PLC CPU-module
CPM2B

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

  • Lineup including CPU Units with built-in three ports: USB, RS-232C, RS-485.
  • The depth of CPU Units with RS-232C connectors is reduced by 20 mm. (N30/40/60S(1))
  • Easy connection with computers using commercially available USB cables.
  • With E30/40/60(S), N30/40/60(S@) or NA20 CPU Units, Add I/O, Analog I/O or Temperature Inputs by Connecting

ETIM for 333282 PLC's (EC000236)
Feature Name Feature Value
Performance level according to EN ISO 13849-1 (EF007399) Level a
Model (EF000010) Compact
SIL according to IEC 61508 (EF009889) None
Voltage type (supply voltage) (EF002991) AC
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Type of memory (EF002996) FLASH
Radio standard UMTS (EF008525) No
Supporting protocol for EtherCAT (EF017564) No
Appendant operation agent (Ex ib) (EF004142) No
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for SERCOS (EF006657) No
IO link master (EF007298) No
Rack-assembly possible (EF007018) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for IEC 60870 (EF016069) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for DNP3 (EF016068) No
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for IEC 61850 Ethernet (EF015389) No
Suitable for rail mounting (EF003972) Yes
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
System accessory (EF004118) No
Certified for UL hazardous location class III (EF017627) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Certified for UL hazardous location class II (EF017625) No
Certified for UL hazardous location class I (EF017622) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for TCP/IP (EF003050) No
Wall mounting/direct mounting (EF007020) Yes
Front built-in possible (EF007016) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Additional program memory possible (EF003029) No
Supporting protocol for SafetyBUS p (EF007527) No
Appendant operation agent (Ex ia) (EF004141) No
Supporting protocol for Modbus (EF003057) No
Redundancy (EF003156) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Supporting protocol for PROFINET CBA (EF007524) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
With optical interface (EF003028) No
With display (EF000458) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Certified for UL hazardous location division 2 (EF017629) No
Certified for UL hazardous location division 1 (EF017628) No
Certified for UL hazardous location group D (propane) (EF017636) No
Supporting protocol for ASI (EF003051) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
Number of HW-interfaces other (EF003027) 0
Memory size (EF002997) 16 kByte
Number of interfaces PROFINET (EF006932) 0
Number of relay outputs (EF007348) 0
Number of HW-interfaces USB (EF003025) 1
Width (EF000008) 66 mm
Number of digital inputs (EF001992) 6
Depth (EF000049) 85 mm
Number of HW-interfaces wireless (EF006933) 0
Number of analogue inputs (EF001994) 0
Number of HW-interfaces parallel (EF003026) 0
Number of digital outputs (EF001993) 4
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of analogue outputs (EF001995) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Processing time (1K, binary operation) (EF003004) 1.1 ms
Number of HW-interfaces RS-485 (EF003023) 0
Height (EF000040) 90 mm
Max. number of time switches (EF007349) 255
Supply voltage AC 60 Hz (EF007533) 85 V
Supply voltage AC 50 Hz (EF007532) 85 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.