View larger
DRT1-COM
DRT11103E
DRT1COM
OMRON
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
CJ-series DeviceNet Unit
CJ1W-DRM21
Smallest in the Industry! A DeviceNet Unit for the CJ Series that Boasts Industry-leading Performance and
Functions
CSM_CJ1W-DRM21_DS_E_8_1
Features
CJ1W-DRM21
• Allows control of up to 32,000 points (2,000 words) per master, and ensures a high degree of simultaneity between data.
• Can be used as both a master and a slave at the same time.
• Equipped with settings and monitor functions aimed at improving both design and startup efficiency. Achieve maximum performance by using in combination with a Configurator.
• Files of master and slave settings can be uploaded and downloaded using memory cards, allowing effective debugging and easier setup.
System Configuration
DeviceNet
Configurator
Control system
Maintenance system
Ethernet
Controller
DRT2-series MIL Connector Terminals
Maintenance information
Common Smart Slave Functions Network power supply voltage monitor Unit/Connected device comments
Unit power-ON time monitor
E5ZN-DRT
Smart Slave DeviceNet
Communications Unit
Control information
DRT2-series
Smart Slave
Remote I/O Terminals
DRT2-series
Remote I/O Terminals Models with 3-tier Terminal Blocks
DRT2-series
Remote I/O Terminals
Relay Output Terminals
DRT2-series
Smart Slave
Analog I/O Terminals
DRT2-series Smart Slave Environment-resistive Terminals
DRT2-series Smart Slave Sensor Terminals
DRT2-series Screw-less Clamp Terminals
Smart Slave: DRT2-series Board Terminals
with MIL Connectors
Reduce Setup Time
• Network power supply monitor function • Moving average processing function
Reduce Downtime
• Unit comments function
Improve Maintenance
• Operation time monitor function
• Input filter function
• Power-ON inrush current protection function
• Communications speed auto-detect function
• Scaling function
• User compensation function
• Cumulative counter
• Number of A/D conversion points
(conversion cycle) setting
• Peak/bottom hold function
• Top/valley hold function
• Percentage change calculation function
• Connected device comments function
• I/O power supply monitor function
• Sensor power supply short-circuit detection function
• External load short-circuit detection function
• Disconnected sensor detection function
• Contact operations counter (See note.)
• Unit conduction time monitor function
• Total ON time monitor function (See note.)
• Network power supply voltage monitor function
• Communications error log function
• Last maintenance date
• Comparator function
• Selectable output value after error
Note: The number of contact operations monitor function and the cumulative ON time monitor function cannot be used simultaneously for the same contact.