EJ1
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Omron EJ1C-EDUC-NFLK removable connector header integrates power, communication, and alarm interfaces for modular industrial controllers. Terminal headers and communication blocks allow technicians to rapidly wire, disconnect, and replace automation modules within complex distributed process control setups.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Basic unit: 2
- Basic unit: 2
- Basic unit: 2
- Basic unit: 2
- Basic unit: 4
- Basic unit: 4
- High function unit: –
- High function unit: –
- DeviceNet unit: –
- 5.8 dia.: E54-CT1
- 12.0 dia.: E54-CT3
- G3ZA connecting cable 5 meter: EJ1C-CBLA050
- USB programming cable: E58-CIFQ1
- PC based configuration and tuning softwareCX-Thermo: EST2-2C-MV4
- PROFIBUS Gateway: PRT1-SCU11
- Power supplyvoltage: 24 VDC
More info
▲CelciuXº - Multi-Loop temperature control - Control and Connectivity
CelciuXº is designed to offer easy program-less communication with Omron and third-party PLCs and HMI. Above all, CelciuXº (EJ1) incorporates all âsimple to useâ clever temperature control technology, like 2-PID, disturbance control and various ways of tuning.
- Interfaces to a wide range of industrial networks
- Reduced engineering due to Programm-less communications, Smart Active Parts and Function Block Libraries
- Available with screw terminals and screw-less clamp terminals
- One unit handling various types of input, such as Pt, Thermocouple, mA, and V input
Applications
The perfect solution for multi-loop control
Reliability, compactness and uncompromising control performance make the CelciuX° the perfect choice for basic multi-loop control.
Multi-loop machine control with hmi
Control, overview and>
Ordering information
| Type | Control points | Control outputs | Auxiliary outputs | Other functions | Terminal | Order code |
|---|---|---|---|---|---|---|
| Basic unit | 2 | 2 voltage (pulse) | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 CT input 2 + 2 event inputWhen usingthe heater burnout alarm, purchase a Current Transformer (E54-CT1or E54-CT3) separately. | M3 screws | EJ1N-TC2A-QNHB |
| Basic unit | 2 | 2 voltage (pulse) | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 CT input 2 +2 event inputWhen usingthe heater burnout alarm, purchase a Current Transformer (E54-CT1or E54-CT3) separately. | Screw-less clamp | EJ1N-TC2B-QNHB |
| Basic unit | 2 | 2 current | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 event input | M3 screws | EJ1N-TC2A-CNB |
| Basic unit | 2 | 2 current | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 event input | Screw-less clamp | EJ1N-TC2B-CNB |
| Basic unit | 4 | 4 voltage (pulse) | – | – | M3 screws | EJ1N-TC4A-QQ |
| Basic unit | 4 | 4 voltage (pulse) | – | – | Screw-less clamp | EJ1N-TC4B-QQ |
| High function unit | – | – | 4 transistor (NPN) | 4 event input | M3 screws | EJ1N-HFUA-NFLK |
| High function unit | – | – | 4 transistor (NPN) | 4 event input | Screw-less clamp | EJ1N-HFUB-NFLK |
| DeviceNet unit | – | – | – | – | Screw connector | EJ1N-HFUB-DRT |
| Ethernet unit 2 This unit mounts to the left of the CelciuX° (EJ1) configuration and enables PROFINET or Modbus/TCP network connection. Combine the HFU-ETN with an EDU_-NFLK end unit to use with other devices supporting Modbus-RTU like E5_N temperature controllers and MX2 Inverters. | – | – | – | – | 3 x RJ45 | EJ1N-HFU-ETN |
| End unit 2 An End unitis always required for connection to a Basic unit or an HFU. AnHFU cannot operate without a Basic unit. | – | – | 2 transistor (NPN) | – | M3 screws | EJ1C-EDUA-NFLK |
| End unit 2 An End unitis always required for connection to a Basic unit or an HFU. AnHFU cannot operate without a Basic unit. | – | – | 2 transistor (NPN) | – | Removable Connector | EJ1C-EDUC-NFLK |
Accessories
Currenttransformer
| Diameter | Order code |
|---|---|
| 5.8 dia. | E54-CT1 |
| 12.0 dia. | E54-CT3 |
Communications and cables
| Description | Order code |
|---|---|
| G3ZA connecting cable 5 meter | EJ1C-CBLA050 |
| USB programming cable | E58-CIFQ1 |
| PC based configuration and tuning softwareCX-Thermo | EST2-2C-MV4 |
| PROFIBUS Gateway | PRT1-SCU11 |
Specifications
| Item | Type | EJ1_-TC2 | EJ1_-TC4 |
|---|---|---|---|
| Power supplyvoltage | 24 VDC | ||
| Operatingvoltage range | 85% to 110% of rated voltage | ||
| Power consumption | 4 W max. (at maximum load) | 5 W max. (at maximum load) | |
| Input (seenote) 2 Inputs are fully multi-input. Therefore, platinum resistancethermometer, thermocouple, infrared thermosensor, and analog inputcan be selected. | Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII ES1B Infrared Thermosensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C. Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 VPlatinumresistance thermometer: Pt100, JPt100 | ||
| Input impedance | Current input: 150Ω max., voltageinput: 1 MΩ min. | ||
| Controloutputs | Voltage output | Output voltage: 12 VDC ±15%, max.load current: 21 mA (PNP models with short-circuit protection circuit) | |
| Transistor output | Max. operating voltage: 30 V, max.load current: 100 mA | – | |
| Current output | Current output range: 4 to 20 mA or 0 to 20mA DCLoad: 500 Ω max. (including transfer output)(Resolution: Approx:2,800 for 4 to 20 mA DC, approx. 3,500 for 0 to 20 mA DC) | – | |
| Event inputs | Input points | 2 | – |
| Contact input | ON: 1 kΩ max., OFF. 100 kΩ min. | – | |
| Non-contact input | ON: Residual voltage: 1.5 V max.,OFF: Leakage current: 0.1 mA max. | – | |
| Outflow current: approx. 4 mA per point | – | ||
| Number ofinput and control points | Input points: 2, control points: 2 | Input points: 4, control points: 4 | |
| Setting method | Via communications | ||
| Control method | ON/OFF control or 2-PID (withautotuning, selftuning, Heat & Cool autotuning and non-linearcool output selection) | ||
| Other functions | Two-point input shift, digital input filter, remote SP, SP ramp, manual manipulated variable, manipulated variable limiter, interference overshoot adjustment, loop burnout alarm, RUN/STOP, banks, I/O allocations, etc. | ||
| Alarm output | 2 points via End unit | ||
| Communication | RS-485, PROFIBUS, Modbus, DeviceNet | RS-485, PROFIBUS, Modbus, DeviceNet | |
| Size in mm(W×H×D) | 31×96×109 | ||
| Weight | 180 g | ||
| Ambient temperaturerange | Operating –10 to 55°C, Storage–25 to 65°C (with no icing or condensation) | ||
| Ambient humidityrange | Operating 25% to 85% (with nocondensation) | ||
Dimensions
| Item | Size in mm (H×W×D) |
|---|---|
| EJ1N-HFU_-NFL_ | 95.4×31.0×104.9/109.0 |
| EJ1N-HFUB-DRT | 90.9×31.0×82.2 |
| EJ1C-EDU | 95.4×15.7×76.2/79.7 |