OMRON EJ1N-HFUB-DRT EJ1N-HFUB-DRT 243922 EJ1NHFUBDRT OMRON EJ1 Mod. Coms Slave DeviceNet View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EJ1N-HFUB-DRT 243922 EJ1NHFUBDRT OMRON EJ1 Mod. Coms Slave DeviceNet

EJ1N-HFUB-DRT

243922

EJ1NHFUBDRT

OMRON

1 Pcs.

EJ1 Mod. Coms Slave DeviceNet

Automation > PLC communication module
EJ1

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Features

CelciuXº - Multi-Loop temperature control - Control and Connectivity

CelciuXº is designed to offer easy program-less communication with Omron and third-party PLCs and HMI. Above all, CelciuXº (EJ1) incorporates all âsimple to useâ clever temperature control technology, like 2-PID, disturbance control and various ways of tuning.

  • Interfaces to a wide range of industrial networks
  • Reduced engineering due to Programm-less communications, Smart Active Parts and Function Block Libraries
  • Available with screw terminals and screw-less clamp terminals
  • One unit handling various types of input, such as Pt, Thermocouple, mA, and V input

Applications

The perfect solution for multi-loop control

Reliability, compactness and uncompromising control performance make the CelciuX° the perfect choice for basic multi-loop control.

Multi-loop machine control with hmi

Control, overview and>

Ordering information

Type Control points Control outputs Auxiliary outputs Other functions Terminal Order code
Basic unit 2 2 voltage (pulse) 2 transistor (NPN)
2
For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control.
On the 4-point models, heating/cooling control can be performed for two input points only.
2 CT input
2
When usingthe heater burnout alarm, purchase a Current Transformer (E54-CT1or E54-CT3) separately.
+ 2 event input
M3 screws EJ1N-TC2A-QNHB
Basic unit 2 2 voltage (pulse) 2 transistor (NPN)
2
For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control.
On the 4-point models, heating/cooling control can be performed for two input points only.
2 CT input
2
When usingthe heater burnout alarm, purchase a Current Transformer (E54-CT1or E54-CT3) separately.
+2 event input
Screw-less clamp EJ1N-TC2B-QNHB
Basic unit 2 2 current 2 transistor (NPN)
2
For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control.
On the 4-point models, heating/cooling control can be performed for two input points only.
2 event input M3 screws EJ1N-TC2A-CNB
Basic unit 2 2 current 2 transistor (NPN)
2
For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control.
On the 4-point models, heating/cooling control can be performed for two input points only.
2 event input Screw-less clamp EJ1N-TC2B-CNB
Basic unit 4 4 voltage (pulse) M3 screws EJ1N-TC4A-QQ
Basic unit 4 4 voltage (pulse) Screw-less clamp EJ1N-TC4B-QQ
High function unit 4 transistor (NPN) 4 event input M3 screws EJ1N-HFUA-NFLK
High function unit 4 transistor (NPN) 4 event input Screw-less clamp EJ1N-HFUB-NFLK
DeviceNet unit Screw connector EJ1N-HFUB-DRT
Ethernet unit
2
This unit mounts to the left of the CelciuX° (EJ1) configuration and enables PROFINET or Modbus/TCP network connection.
Combine the HFU-ETN with an EDU_-NFLK end unit to use with other devices supporting Modbus-RTU like E5_N temperature controllers and MX2 Inverters.
3 x RJ45 EJ1N-HFU-ETN
End unit
2
An End unitis always required for connection to a Basic unit or an HFU. AnHFU cannot operate without a Basic unit.
2 transistor (NPN) M3 screws EJ1C-EDUA-NFLK
End unit
2
An End unitis always required for connection to a Basic unit or an HFU. AnHFU cannot operate without a Basic unit.
2 transistor (NPN) Removable Connector EJ1C-EDUC-NFLK

Accessories

Currenttransformer

Diameter Order code
5.8 dia. E54-CT1
12.0 dia. E54-CT3

Communications and cables

Description Order code
G3ZA connecting cable 5 meter EJ1C-CBLA050
USB programming cable E58-CIFQ1
PC based configuration and tuning softwareCX-Thermo EST2-2C-MV4
PROFIBUS Gateway PRT1-SCU11

Specifications

Item Type EJ1_-TC2 EJ1_-TC4
Power supplyvoltage 24 VDC
Operatingvoltage range 85% to 110% of rated voltage
Power consumption 4 W max. (at maximum load) 5 W max. (at maximum load)
Input (seenote)
2
Inputs are fully multi-input. Therefore, platinum resistancethermometer, thermocouple, infrared thermosensor, and analog inputcan be selected.
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII
ES1B Infrared Thermosensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C.
Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 VPlatinumresistance thermometer: Pt100, JPt100
Input impedance Current input: 150Ω max., voltageinput: 1 MΩ min.
Controloutputs Voltage output Output voltage: 12 VDC ±15%, max.load current: 21 mA (PNP models with short-circuit protection circuit)
Transistor output Max. operating voltage: 30 V, max.load current: 100 mA
Current output Current output range: 4 to 20 mA or 0 to 20mA DCLoad: 500 Ω max. (including transfer output)(Resolution: Approx:2,800 for 4 to 20 mA DC, approx. 3,500 for 0 to 20 mA DC)
Event inputs Input points 2
Contact input ON: 1 kΩ max., OFF. 100 kΩ min.
Non-contact input ON: Residual voltage: 1.5 V max.,OFF: Leakage current: 0.1 mA max.
Outflow current: approx. 4 mA per point
Number ofinput and control points Input points: 2, control points: 2 Input points: 4, control points: 4
Setting method Via communications
Control method ON/OFF control or 2-PID (withautotuning, selftuning, Heat & Cool autotuning and non-linearcool output selection)
Other functions Two-point input shift, digital input filter, remote SP, SP ramp, manual manipulated variable,
manipulated variable limiter, interference overshoot adjustment, loop burnout alarm, RUN/STOP, banks, I/O allocations, etc.
Alarm output 2 points via End unit
Communication RS-485, PROFIBUS, Modbus, DeviceNet RS-485, PROFIBUS, Modbus, DeviceNet
Size in mm(W×H×D) 31×96×109
Weight 180 g
Ambient temperaturerange Operating –10 to 55°C, Storage–25 to 65°C (with no icing or condensation)
Ambient humidityrange Operating 25% to 85% (with nocondensation)

Dimensions

Item Size in mm (H×W×D)
EJ1N-HFU_-NFL_ 95.4×31.0×104.9/109.0
EJ1N-HFUB-DRT 90.9×31.0×82.2
EJ1C-EDU 95.4×15.7×76.2/79.7

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.