OBO BETTERMANN OKA-W5004030 OKA-W5004030 7424406 OBO BETTERMANN Flushfloor trunking unit blank, 2400x500x40, Strip-galvanised, DIN EN 10.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

OKA-W5004030 7424406 OBO BETTERMANN Flushfloor trunking unit blank, 2400x500x40, Strip-galvanised, DIN EN 10..

OKA-W5004030

7424406

OBO BETTERMANN

2 Pcs.

Flushfloor trunking unit blank, 2400x500x40, Strip-galvanised, DIN EN 10147, Steel, St OKA-W5004030 flush pavement channel, blind 2400x500x40 Steel, St, strip galvanized, DIN EN 10346 Trunking unit, blank, height 40−70 mm. Ready-to-mount trunking unit with three blanking lids for cable laying, consisting of the trunking base (floor trough with side and floor covering contact profiles) and trunking lid. Floor trough with holding straps for self-contacting mounting of separating retainers. The scope of delivery contains 6 height-adjustable fixing brackets, 6 screed anchors and lid butt seals (3x for nominal trunking widths of 200 and 300) or height-adjustable lid butt supports: 3x for nominal trunking width 400 and 6x for nominal trunking widths 500 and 600. Trunking lid screwed on for delivery.

Automation > Underfloor installation duct flush floor open
Other

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

CO2 Footprint (GWP) Cradle-to-Gate93,2942 kg CO2e / 1 Meter
Cover fastening, lockingno
Cover material thickness4
Covers3
Decouplableno
Dimension2400x500x40
Duct height, min.40 mm
Floor plateyes
Height-adjustment range, max.70 mm
Height-adjustment range, min.40 mm
Installation opening for on-floor tankno
Length2400 mm
MaterialSteel
Minimum screed height40
Mounting openingWithout
Mounting opening coverno
Number of compartments3 St.
Number of insertable partitions2
Number of planned flush-mount units3
Removable coveryes
Seal installation optionyes
Separating retainer fasteningLock
Suitable for expansion jointno
SurfaceStrip galvanized
Trunking height, max.70 mm
Usable cross-section8500 mm²
Width500 mm
With connection openingno
With equipotential bondingno
With overhangyes
With separating retainerno

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.