OBO BETTERMANN OKA-W30010050D4 OKA-W30010050D4 7424620 OBO BETTERMANN Flushfloor trunking unit for service unit GES18, 2400x300x100, Strip-.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

OKA-W30010050D4 7424620 OBO BETTERMANN Flushfloor trunking unit for service unit GES18, 2400x300x100, Strip-..

OKA-W30010050D4

7424620

OBO BETTERMANN

2 Pcs.

Flushfloor trunking unit for service unit GES18, 2400x300x100, Strip-galvanised, DIN EN 10147, Steel, St OKA-W30010050D4 pavement flush channel, for conj. portam. GES4 2400x300x100 Steel, St, strip galvanized, DIN EN 10346 Trunking unit for GES4, height 100−150 mm. Ready-to-mount trunking unit with three or six device installation lids for cable laying and the installation of flush-mount units of nominal size 4, consisting of the trunking base (floor trough with side and floor covering contact profiles) and trunking lid with blank covered mounting opening. Floor trough with holding straps for self-contacting mounting of separating retainers. The scope of delivery contains 6 height-adjustable fixing brackets, 6 screed anchors and lid butt seals (3x for nominal trunking widths of 200 and 300) or height-adjustable lid butt supports: 3x for nominal trunking width 400 and 6x for nominal trunking widths 500 and 600. Trunking lid screwed down when delivered.

Automation > Underfloor installation duct flush floor open
Other

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

CO2 Footprint (GWP) Cradle-to-Gate64,7423 kg CO2e / 1 Meter
Cover fastening, lockingno
Cover material thickness4
Covers3
Decouplableno
Dimension2400x300x100
Duct height, min.100 mm
Floor plateyes
Height-adjustment range, max.150 mm
Height-adjustment range, min.100 mm
Installation opening for on-floor tankno
Length2400 mm
MaterialSteel
Minimum screed height100
Mounting openingSquare
Mounting openingFor service outlet
Mounting opening coveryes
Nominal size for device installation units4
Number of compartments3 St.
Number of insertable partitions2
Number of planned flush-mount units3
Removable coveryes
Seal installation optionyes
Separating retainer fasteningPlug
Suitable for expansion jointno
SurfaceStrip galvanized
Trunking height, max.150 mm
Width300 mm
With connection openingyes
With equipotential bondingno
With overhangyes
With separating retainerno

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.