View larger
OKA-W A 4030R9 7424886 OBO BETTERMANN Extension unit for OKA-W, Strip-galvanised, DIN EN 10147, Steel, St
OKA-W A 4030R9
7424886
OBO BETTERMANN
1 Pcs.
Automation > Underfloor installation duct flush floor open
Other
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Obo Bettermann part number OKA-W A 4030R9 functions as an extension unit for OKA-W, enabling customized configuration and connection adjustments in underfloor duct installations. These modular components help installers adapt standard routing layouts to complex architectural floor plans.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- CO2 Footprint (GWP) Cradle-to-Gate: 48,9966 kg CO2e / 1 Piece
- Cover fastening, locking: no
- Cover material thickness: 4
- Covers: 1
- Decouplable: no
- Dimension A: 400 mm
- Dimension d Ø: 305 mm
- Dimension h: 40 mm
- Duct height, min.: 40 mm
- Height-adjustment range, max.: 70 mm
- Height-adjustment range, min.: 40 mm
- Installation opening for flush-mount unit: Round
- Installation opening for on-floor tank: no
- Length: 473 mm
- Material: Steel
- Minimum screed height: 40
More info
▲| CO2 Footprint (GWP) Cradle-to-Gate | 48,9966 kg CO2e / 1 Piece |
|---|---|
| Cover fastening, locking | no |
| Cover material thickness | 4 |
| Covers | 1 |
| Decouplable | no |
| Dimension A | 400 mm |
| Dimension d Ø | 305 mm |
| Dimension h | 40 mm |
| Duct height, min. | 40 mm |
| Height-adjustment range, max. | 70 mm |
| Height-adjustment range, min. | 40 mm |
| Installation opening for flush-mount unit | Round |
| Installation opening for on-floor tank | no |
| Length | 473 mm |
| Material | Steel |
| Minimum screed height | 40 |
| Mounting opening | For service outlet |
| Mounting opening cover | yes |
|---|---|
| Nominal size for device installation units | R9 |
| Number of mounting openings | 1 |
| Removable cover | yes |
| Seal installation option | yes |
| Suitable for expansion joint | no |
| Suitable for flushfloor, open underfloor trunking | yes |
| Suitable for screed-covered underfloor ducts | no |
| Suitable for screed-flush closed underfloor ducts | no |
| Surface | Strip galvanized |
| Trunking height, max. | 70 mm |
| Width | 400 mm |
| With connection opening | yes |
| With equipotential bonding | no |
| With overhang | yes |
| With separating retainer | no |