OBO BETTERMANN OKA-W A 10050 4 OKA-W A 10050 4 7424920 OBO BETTERMANN Extension unit for OKA-W, Strip-galvanised, DIN EN 10147, Steel, St View larger
Images are for illustrative purposes only. Please refer to data sheet for details

OKA-W A 10050 4 7424920 OBO BETTERMANN Extension unit for OKA-W, Strip-galvanised, DIN EN 10147, Steel, St

OKA-W A 10050 4

7424920

OBO BETTERMANN

1 Pcs.

Extension unit for OKA-W, Strip-galvanised, DIN EN 10147, Steel, St Extension unit for GES4, height 100−150 mm. Ready-to-mount trunking extension unit with a device installation lid for the installation of an installation unit of nominal size 4, consisting of the trunking base (floor trough with side and floor covering guide profiles), trunking lid with blank mounting opening and a flushfloor end cover. The scope of delivery contains three height-adjustable wall fixing brackets, three screed anchors and trunking connection brackets.

Automation > Underfloor installation duct flush floor open
Other

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Extension unit for OKA-W acts as an auxiliary channel piece used to branch or extend underfloor cable ducting networks within commercial screed flooring. This Obo Bettermann component, part number OKA-W A 10050 4, maintains consistent mechanical protection for electrical conductors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • CO2 Footprint (GWP) Cradle-to-Gate: 50,532 kg CO2e / 1 Piece
  • Cover fastening, locking: no
  • Cover material thickness: 4
  • Covers: 1
  • Decouplable: no
  • Dimension A: 400 mm
  • Dimension a: 201 mm
  • Dimension h: 100 mm
  • Duct height, min.: 100 mm
  • Floor plate: no
  • Height-adjustment range, max.: 150 mm
  • Height-adjustment range, min.: 100 mm
  • Installation opening for flush-mount unit: Square
  • Installation opening for on-floor tank: no
  • Length: 473 mm
  • Material: Steel

More info

▲
CO2 Footprint (GWP) Cradle-to-Gate50,532 kg CO2e / 1 Piece
Cover fastening, lockingno
Cover material thickness4
Covers1
Decouplableno
Dimension A400 mm
Dimension a201 mm
Dimension h100 mm
Duct height, min.100 mm
Floor plateno
Height-adjustment range, max.150 mm
Height-adjustment range, min.100 mm
Installation opening for flush-mount unitSquare
Installation opening for on-floor tankno
Length473 mm
MaterialSteel
Minimum screed height100
Mounting openingFor service outlet
Mounting opening coveryes
Nominal size for device installation units4
Number of mounting openings1
Removable coveryes
Seal installation optionyes
Suitable for expansion jointno
Suitable for flushfloor, open underfloor trunkingyes
Suitable for screed-covered underfloor ductsno
Suitable for screed-flush closed underfloor ductsno
SurfaceStrip galvanized
Trunking height, max.150 mm
Width400 mm
With connection openingyes
With equipotential bondingno
With overhangyes
With separating retainerno

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.