View larger
VG-C DC-TS1000 5088660 OBO BETTERMANN Surge protection device 2 PV string w. circuit breaker,
VG-C DC-TS1000
5088660
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for power supply systems
Surge , photovoltaics
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as a complete pre-wired junction box, the VG-C DC-TS1000 5088660 OBO BETTERMANN Surge protection device 2 PV string w. circuit breaker combines overvoltage protection and switching capabilities for photovoltaic arrays. This pre-assembled unit manages two strings to safely disconnect DC power and divert lightning surges in solar installations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Anschlussart Generatoranschlusskasten: Tension spring terminal
- CO2 Footprint (GWP) Cradle-to-Gate: 2,644 kg CO2e / 1 Piece
- Colour: Light grey
- RAL 7035:
- Conductor cross-section, rigid (single-wire/multiwire), max.: 6 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 0,5 mm²
- DC network form: yes
- Depth: 122 mm
- Dimension: 1000V DC
- Entries per MPPT: 1
- Equipped with load-break switch: yes
- Exits per MPPT: 1
- Installation type: Pre-mounted in the housing
- IT network form: no
- Lightning protection zone LPZ: 1→2
- Max. Input current per string: 30 A
- Max. Input voltage DC: 1000 V
More info
▲| Anschlussart Generatoranschlusskasten | Tension spring terminal |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 2,644 kg CO2e / 1 Piece |
| Colour | Light grey; RAL 7035 |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 6 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 0,5 mm² |
| DC network form | yes |
| Depth | 122 mm |
| Dimension | 1000V DC |
| Entries per MPPT | 1 |
| Equipped with load-break switch | yes |
| Exits per MPPT | 1 |
| Installation type | Pre-mounted in the housing |
| IT network form | no |
| Lightning protection zone LPZ | 1→2 |
| Max. Input current per string | 30 A |
| Max. Input voltage DC | 1000 V |
| Max. Output current | 30 A |
| Maximum continuous voltage DC | 1000 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Monitoring function | no |
| Network form | DC |
| Nominal discharge current (8/20 µs) | 20 kA |
| Number of cable entries | 16 |
| Number of inputs | 1 |
|---|---|
| Number of MPPTs | 1 |
| Number of string inputs | 1 |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Protection rating | IP65 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| String fuse | Without |
| TN network form | no |
| TN-C network form | no |
| TN-C-S network form | no |
| TN-S network form | no |
| TT network form | no |
| Type of entry | Gland |
| Version for | Type 2 and Benedikt LS32-SMA-A4 DC isolator |