Surge protection device 2 PV string w. circuit breaker, Generator connection box, type 2, up to 1,000 V DC with disconnection switch (32 A) for 1 x 1 string. System solution for circuit breaker photovoltaic inverter with 1 MPP tracker• Varistor arrester, connectable with cut-off unit in error-resistant Y circuit to VDE 0100-712 (50539-12) • Low DC protection level: < 4.0 kV (Voc max = 1,000 V DC with V2ß-B+C/0-500PV) • Circuit breaker (1,000 V; 32 A) for secure switch-off of the DC string cable• Per protection device, there is 1 terminal up to 6 mm² pre-mounted in the housing, up to 30 A DC per terminal • Pre-mounted in polycarbonate housing (IP65), UV-resistant for use outside, including cable gland kitFor DC protection of the inverter in photovoltaic systems.If there is a danger of condensation forming through wind, ice, temperature or sunl

Automation > Surge protection device for power supply systems
Surge , photovoltaics

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Serving as a complete pre-wired junction box, the VG-C DC-TS1000 5088660 OBO BETTERMANN Surge protection device 2 PV string w. circuit breaker combines overvoltage protection and switching capabilities for photovoltaic arrays. This pre-assembled unit manages two strings to safely disconnect DC power and divert lightning surges in solar installations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Anschlussart Generatoranschlusskasten: Tension spring terminal
  • CO2 Footprint (GWP) Cradle-to-Gate: 2,644 kg CO2e / 1 Piece
  • Colour: Light grey
  • RAL 7035:
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 6 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 0,5 mm²
  • DC network form: yes
  • Depth: 122 mm
  • Dimension: 1000V DC
  • Entries per MPPT: 1
  • Equipped with load-break switch: yes
  • Exits per MPPT: 1
  • Installation type: Pre-mounted in the housing
  • IT network form: no
  • Lightning protection zone LPZ: 1→2
  • Max. Input current per string: 30 A
  • Max. Input voltage DC: 1000 V

More info

▲
Anschlussart GeneratoranschlusskastenTension spring terminal
CO2 Footprint (GWP) Cradle-to-Gate2,644 kg CO2e / 1 Piece
ColourLight grey; RAL 7035
Conductor cross-section, rigid (single-wire/multiwire), max.6 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.0,5 mm²
DC network formyes
Depth122 mm
Dimension1000V DC
Entries per MPPT1
Equipped with load-break switchyes
Exits per MPPT1
Installation typePre-mounted in the housing
IT network formno
Lightning protection zone LPZ1→2
Max. Input current per string30 A
Max. Input voltage DC1000 V
Max. Output current30 A
Maximum continuous voltage DC1000 V
Maximum discharge current (8/20 μs)40 kA
Monitoring functionno
Network formDC
Nominal discharge current (8/20 µs)20 kA
Number of cable entries16
Number of inputs1
Number of MPPTs1
Number of string inputs1
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Protection ratingIP65
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
String fuseWithout
TN network formno
TN-C network formno
TN-C-S network formno
TN-S network formno
TT network formno
Type of entryGland
Version forType 2 and Benedikt LS32-SMA-A4 DC isolator