OBO BETTERMANN V50-B+C 3PHFS600 V50-B+C 3PHFS600 5093625 OBO BETTERMANN CombiController V50 three-pole for PV systems + FS, 600V DC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V50-B+C 3PHFS600 5093625 OBO BETTERMANN CombiController V50 three-pole for PV systems + FS, 600V DC,

V50-B+C 3PHFS600

5093625

OBO BETTERMANN

1 Pcs.

CombiController V50 three-pole for PV systems + FS, 600V DC, PV combination arrester V50, 600 V DC with remote signalling. V50 combination arrester, type 1+2, for PV systems with FS contact as potential-free changeover• Complete unit, consisting of plug-in varistor arrester with cut-off unit• Error-resistant Y circuit for use according to VDE 0100-712 (EN 50539-12)• Surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• Arresting capacity to 12.5 kA (10/350) and 50 kA (8/20) per pole• Low DC voltage protection level: < 2.6 kV and Voc max. = 600 V DC• With visual display for use in distributor housingsApplication: PV systems with lightning protection system

Automation > Combined arrester for power supply systems
Surge , photovoltaics

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Built for specialized DC applications, the V50-B+C 3PHFS600 5093625 OBO BETTERMANN CombiController V50 three-pole for PV systems + FS, 600V DC, is a surge protection device tailored for photovoltaic installations. It safely diverts high current surges generated by atmospheric discharges away from sensitive inverter electronics. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 1,0117 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • DC network form: yes
  • Dimension: 600V DC
  • FM contacts: Changeover
  • Installation type: DIN rail 35 mm
  • IT network form: no
  • Lightning protection zone LPZ: 0→2
  • Lightning surge current (10/350 μs): 12,5 kA
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage DC: 600 V
  • Maximum discharge current (8/20 μs): 50 kA
  • Network form: DC

More info

▲
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate1,0117 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
DC network formyes
Dimension600V DC
FM contactsChangeover
Installation typeDIN rail 35 mm
IT network formno
Lightning protection zone LPZ0→2
Lightning surge current (10/350 μs)12,5 kA
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage DC600 V
Maximum discharge current (8/20 μs)50 kA
Network formDC
Nominal discharge current (8/20 µs)30 kA
Nominal discharge current (8/20 µs) [L-N]30 kA
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version3
Protection ratingIP20
Remote signallingyes
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
TN network formno
TN-C network formno
TN-C-S network formno
TN-S network formno
TT network formno
Version for3-pole for PV systems with FS

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.