View larger
V50-B+C 3PHFS600 5093625 OBO BETTERMANN CombiController V50 three-pole for PV systems + FS, 600V DC,
V50-B+C 3PHFS600
5093625
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , photovoltaics
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for specialized DC applications, the V50-B+C 3PHFS600 5093625 OBO BETTERMANN CombiController V50 three-pole for PV systems + FS, 600V DC, is a surge protection device tailored for photovoltaic installations. It safely diverts high current surges generated by atmospheric discharges away from sensitive inverter electronics. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 1,0117 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- DC network form: yes
- Dimension: 600V DC
- FM contacts: Changeover
- Installation type: DIN rail 35 mm
- IT network form: no
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 12,5 kA
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage DC: 600 V
- Maximum discharge current (8/20 μs): 50 kA
- Network form: DC
More info
▲| Blow-out | no |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 1,0117 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | yes |
| Dimension | 600V DC |
| FM contacts | Changeover |
| Installation type | DIN rail 35 mm |
| IT network form | no |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 12,5 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage DC | 600 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | DC |
| Nominal discharge current (8/20 µs) | 30 kA |
| Nominal discharge current (8/20 µs) [L-N] | 30 kA |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 3 |
| Protection rating | IP20 |
| Remote signalling | yes |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| TN network form | no |
| TN-C network form | no |
| TN-C-S network form | no |
| TN-S network form | no |
| TT network form | no |
| Version for | 3-pole for PV systems with FS |