Engineered for photovoltaic applications, the V50-B+C 3-PH600 5093623 OBO BETTERMANN CombiController V50 three-pole for photovoltaics, 600V, by Obo Bettermann delivers specialized direct current surge suppression. Solar power generation facilities rely on such multi-pole controllers to prevent atmospheric and switching surges from damaging DC distribution arrays. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 30 kA
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 1,0101 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- DC network form: yes
- Dimension: 600V DC
- Installation type: DIN rail 35 mm
- IT network form: no
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 12,5 kA
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage DC: 600 V
- Maximum discharge current (8/20 μs): 50 kA
- Network form: DC
More info
▲| Arrester surge current (8/20 µs) [total] | 30 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 1,0101 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | yes |
| Dimension | 600V DC |
| Installation type | DIN rail 35 mm |
| IT network form | no |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 12,5 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage DC | 600 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | DC |
| Nominal discharge current (8/20 µs) | 30 kA |
| Nominal discharge current (8/20 µs) [L-N] | 30 kA |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 3 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| TN network form | no |
| TN-C network form | no |
| TN-C-S network form | no |
| TN-S network form | no |
| TT network form | no |
| Version for | 3-pole for PV systems |