V50-B+C 0-300PV 5093726 OBO BETTERMANN CombiController V50 plug-in arrester f. PV systems, 300V DC,
V50-B+C 0-300PV
5093726
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , photovoltaics
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The V50-B+C 0-300PV 5093726 OBO BETTERMANN CombiController V50 plug-in arrester f. PV systems, 300V DC, manufactured by Obo Bettermann delivers specialized overvoltage protection for solar energy installations. Photovoltaic applications require robust DC surge arresters to prevent environmental lightning strikes from destroying expensive inverter technology. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrester surge current (8/20 µs) [total]: 30 kA
- CO2 Footprint (GWP) Cradle-to-Gate: 0,1893 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- Dimension: 300V DC
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 12,5 kA
- Lightning surge current (10/350): 12,5 kA
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage AC: 280 V
- Maximum continuous voltage DC: 300 V
- Maximum discharge current (8/20 μs): 50 kA
- Nominal discharge current (8/20 µs): 30 kA
- Nominal discharge current (8/20 µs) [L-N]: 30 kA
- Operating temperature, max.: 80 °C
More info
▲| Arrester surge current (8/20 µs) [total] | 30 kA |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 0,1893 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| Dimension | 300V DC |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 12,5 kA |
| Lightning surge current (10/350) | 12,5 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage AC | 280 V |
| Maximum continuous voltage DC | 300 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Nominal discharge current (8/20 µs) | 30 kA |
|---|---|
| Nominal discharge current (8/20 µs) [L-N] | 30 kA |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 1 |
| Protection level [L-N] | ≤1,3 |
| Protection rating | IP20 |
| Response time | <25 ns |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| Version for | 1-pole, PV upper part with Y base to 600 V DC |