V25-B+C 3-PH900 5097447 OBO BETTERMANN CombiController V25 three-pole for photovoltaics, 900V,
V25-B+C 3-PH900
5097447
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for power supply systems
Surge , photovoltaics
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This V25-B+C 3-PH900 5097447 OBO BETTERMANN CombiController V25 three-pole for photovoltaics, 900V, is a dedicated surge protective device engineered to safeguard solar power generation systems. Installed within DC combiner boxes or inverter inputs, it intercepts transient overvoltages and prevents damage to string components. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 0,9501 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- DC network form: yes
- Dimension: 900V DC
- Installation type: DIN rail 35 mm
- IT network form: no
- Lightning protection zone LPZ: 0→2
- Lightning surge current (10/350 μs): 7 kA
- Max. mains-side overcurrent protection: 160
- Maximum back-up fuse: 160 A
- Maximum continuous voltage DC: 900 V
- Maximum discharge current (8/20 μs): 50 kA
- Network form: DC
- Nominal discharge current (8/20 µs): 30 kA
More info
▲| Blow-out | no |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 0,9501 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | yes |
| Dimension | 900V DC |
| Installation type | DIN rail 35 mm |
| IT network form | no |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 7 kA |
| Max. mains-side overcurrent protection | 160 |
| Maximum back-up fuse | 160 A |
| Maximum continuous voltage DC | 900 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | DC |
| Nominal discharge current (8/20 µs) | 30 kA |
| Nominal discharge current (8/20 µs) [L-N] | 30 kA |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
|---|---|
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 3 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| TN network form | no |
| TN-C network form | no |
| TN-C-S network form | no |
| TN-S network form | no |
| TT network form | no |
| Version for | 3-pole for PV systems |