OBO BETTERMANN V20-C 3PHFS-600 V20-C 3PHFS-600 5094576 OBO BETTERMANN SurgeController V20 three-pole for PV systems + FS, 600V DC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V20-C 3PHFS-600 5094576 OBO BETTERMANN SurgeController V20 three-pole for PV systems + FS, 600V DC,

V20-C 3PHFS-600

5094576

OBO BETTERMANN

1 Pcs.

SurgeController V20 three-pole for PV systems + FS, 600V DC, PV surge protection V20, 600 V DC with remote signalling. V20 surge arrester, type 2, for PV systems with FS contact as potential-free changeover• Complete unit, consisting of plug-in varistor arrester with cut-off unit• Error-resistant Y circuit for use according to VDE 0100-712 (EN 50539-12)• For surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• Arresting capacity to 40 kA (8/20) per pole• Low DC protection level: < 2.6 kV (Voc max = 600 V DC)• Arrester, connectable with thermodynamic cut-off unit and visual function display• Encapsulated, zinc oxide varistor arrester for use in distributor housings Application: PV systems with or without separate lightning protection system

Automation > Surge protection device for power supply systems
Surge , photovoltaics

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Engineered for photovoltaic DC power architectures, the Obo Bettermann V20-C 3PHFS-600 SurgeController protects solar inverters and array wiring from dangerous lightning-induced surges. Integrated changeover contacts allow for reliable remote status monitoring across the installation.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Blow-out: no
  • CO2 Footprint (GWP) Cradle-to-Gate: 1,0775 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • Dimension: 600V DC
  • FM contacts: Changeover
  • Installation type: DIN rail 35 mm
  • Lightning protection zone LPZ: 1→2
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage DC: 600 V
  • Maximum discharge current (8/20 μs): 40 kA
  • Nominal discharge current (8/20 µs): 20 kA
  • Operating temperature, max.: 80 °C
  • Operating temperature, min.: -40 °C
  • Permitted temperature range, max.: 80 °C

More info

▲
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate1,0775 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
Dimension600V DC
FM contactsChangeover
Installation typeDIN rail 35 mm
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage DC600 V
Maximum discharge current (8/20 μs)40 kA
Network formOther
Nominal discharge current (8/20 µs)20 kA
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version3
Protection level wire-earth< 2,6 V
Protection level wire-wire< 2,6 V
Protection ratingIP20
Remote signallingyes
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
Version for3-pole for PV systems; Y circuit with FS

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.