The V20-C 2-PH-1000 5094617 OBO BETTERMANN SurgeController V20 two-pole surge arrester is engineered to protect photovoltaic power generation systems from direct and indirect atmospheric surges. Designed specifically for high-voltage DC circuits, this two-pole module integrates into string combiner boxes to safeguard inverters. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Blow-out: no
- CO2 Footprint (GWP) Cradle-to-Gate: 0,8821 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- DC network form: yes
- Dimension: 1000V DC
- Installation type: DIN rail 35 mm
- Lightning protection zone LPZ: 1→2
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage DC: 1000 V
- Maximum discharge current (8/20 μs): 40 kA
- Nominal discharge current (8/20 µs): 20 kA
- Operating temperature, max.: 80 °C
- Operating temperature, min.: -40 °C
- Permitted temperature range, max.: 80 °C
More info
▲| Blow-out | no |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 0,8821 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | yes |
| Dimension | 1000V DC |
| Installation type | DIN rail 35 mm |
| Lightning protection zone LPZ | 1→2 |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage DC | 1000 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) | 20 kA |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 2 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| Test class, type 2 | yes |
| Version for | 2-pole for earthed PV systems |