OBO BETTERMANN V20-C 0-500PV V20-C 0-500PV 5099708 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 500V DC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V20-C 0-500PV 5099708 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 500V DC,

V20-C 0-500PV

5099708

OBO BETTERMANN

1 Pcs.

SurgeController V20 plug-in arrester f. PV systems, 500V DC, PV SurgeController V20, plug-in arrester, type 2. SurgeController upper part - type 2, surge arrester for photovoltaic systems• For surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• Arresting capacity to 40 kA (8/20) per pole• Low DC voltage protection level: < 2.0 kV per pole (Y circuit: 4.0 kV and Voc max = 1,000 V DC)• Plug-in arrester with thermodynamic cut-off unit and visual function display• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in distributor housings• High current carrying capacity with long lifespan Application example: PV systems with or without separated insulated lightning protection system

Automation > Surge protection device for power supply systems
Surge , photovoltaics

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Engineered specifically for photovoltaic applications, the V20-C 0-500PV 5099708 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 500V DC, provides reliable DC-side voltage limitation. Such plug-in arresters are deployed in solar inverter setups to protect DC circuits from atmospheric overvoltages and ensure continuous system operation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • CO2 Footprint (GWP) Cradle-to-Gate: 0,1602 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • DC network form: yes
  • Dimension: 500V DC
  • Installation type: On basic element
  • Integrated back-up fuse: no
  • IT network form: no
  • Lightning protection zone LPZ: 1→2
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage AC: 440 V
  • Maximum continuous voltage DC: 500 V
  • Maximum discharge current (8/20 μs): 40 kA
  • Network form: TN
  • Nominal discharge current (8/20 µs): 20 kA

More info

▲
CO2 Footprint (GWP) Cradle-to-Gate0,1602 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
DC network formyes
Dimension500V DC
Installation typeOn basic element
Integrated back-up fuseno
IT network formno
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage AC440 V
Maximum continuous voltage DC500 V
Maximum discharge current (8/20 μs)40 kA
Network formTN
Nominal discharge current (8/20 µs)20 kA
Nominal voltage AC (50/60 Hz)400 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version1
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
TN network formyes
TN-C network formyes
TN-C-S network formyes
TN-S network formyes
TT network formyes
Version for1-pole, PV upper part with Y base to 1,000 V DC

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.