OBO BETTERMANN V20-C 0-300PV V20-C 0-300PV 5099611 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 300V DC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

V20-C 0-300PV 5099611 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 300V DC,

V20-C 0-300PV

5099611

OBO BETTERMANN

1 Pcs.

SurgeController V20 plug-in arrester f. PV systems, 300V DC, PV SurgeController V20, plug-in arrester, type 2. SurgeController upper part - type 2, surge arrester for photovoltaic systems• For surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• Arresting capacity to 40 kA (8/20) per pole• Low DC voltage protection level: < 1.3 kV per pole (Y circuit: 2.6 kV and Voc max = 600 V DC)• Plug-in arrester with thermodynamic cut-off unit and visual function display• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in distributor housings• High current carrying capacity with long lifespan Application example: PV systems with or without separated insulated lightning protection system

Automation > Surge protection device for power supply systems
Surge , photovoltaics

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Engineered specifically for solar energy installations, the V20-C 0-300PV 5099611 OBO BETTERMANN SurgeController V20 plug-in arrester acts as a dedicated photovoltaic surge protection device. These modules are installed within DC combiners or inverter setups to mitigate lightning-induced transients and atmospheric overvoltages on photovoltaic panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • CO2 Footprint (GWP) Cradle-to-Gate: 0,1685 kg CO2e / 1 Piece
  • Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
  • Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
  • DC network form: yes
  • Dimension: 300V DC
  • Installation type: On basic element
  • Integrated back-up fuse: no
  • IT network form: no
  • Lightning protection zone LPZ: 1→2
  • Max. mains-side overcurrent protection: 125
  • Maximum back-up fuse: 125 A
  • Maximum continuous voltage AC: 300 V
  • Maximum continuous voltage DC: 300 V
  • Maximum discharge current (8/20 μs): 40 kA
  • Network form: TN
  • Nominal discharge current (8/20 µs): 20 kA

More info

▲
CO2 Footprint (GWP) Cradle-to-Gate0,1685 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
DC network formyes
Dimension300V DC
Installation typeOn basic element
Integrated back-up fuseno
IT network formno
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage AC300 V
Maximum continuous voltage DC300 V
Maximum discharge current (8/20 μs)40 kA
Network formTN
Nominal discharge current (8/20 µs)20 kA
Nominal voltage AC (50/60 Hz)400 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version1
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
TN network formyes
TN-C network formyes
TN-C-S network formyes
TN-S network formyes
TT network formyes
Version for1-pole, PV upper part with Y base to 600 V DC

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.