V20-C 0-300PV 5099611 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 300V DC,
V20-C 0-300PV
5099611
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for power supply systems
Surge , photovoltaics
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered specifically for solar energy installations, the V20-C 0-300PV 5099611 OBO BETTERMANN SurgeController V20 plug-in arrester acts as a dedicated photovoltaic surge protection device. These modules are installed within DC combiners or inverter setups to mitigate lightning-induced transients and atmospheric overvoltages on photovoltaic panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- CO2 Footprint (GWP) Cradle-to-Gate: 0,1685 kg CO2e / 1 Piece
- Conductor cross-section, rigid (single-wire/multiwire), max.: 35 mm²
- Conductor cross-section, rigid (single-wire/multiwire), min.: 2,5 mm²
- DC network form: yes
- Dimension: 300V DC
- Installation type: On basic element
- Integrated back-up fuse: no
- IT network form: no
- Lightning protection zone LPZ: 1→2
- Max. mains-side overcurrent protection: 125
- Maximum back-up fuse: 125 A
- Maximum continuous voltage AC: 300 V
- Maximum continuous voltage DC: 300 V
- Maximum discharge current (8/20 μs): 40 kA
- Network form: TN
- Nominal discharge current (8/20 µs): 20 kA
More info
▲| CO2 Footprint (GWP) Cradle-to-Gate | 0,1685 kg CO2e / 1 Piece |
|---|---|
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | yes |
| Dimension | 300V DC |
| Installation type | On basic element |
| Integrated back-up fuse | no |
| IT network form | no |
| Lightning protection zone LPZ | 1→2 |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage AC | 300 V |
| Maximum continuous voltage DC | 300 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Network form | TN |
| Nominal discharge current (8/20 µs) | 20 kA |
| Nominal voltage AC (50/60 Hz) | 400 V |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
|---|---|
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 1 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| Test class, type 2 | yes |
| TN network form | yes |
| TN-C network form | yes |
| TN-C-S network form | yes |
| TN-S network form | yes |
| TT network form | yes |
| Version for | 1-pole, PV upper part with Y base to 600 V DC |