OBO BETTERMANN USS 45-A-RW ÜSS 45-A-RW 6117465 OBO BETTERMANN Surge protection Modul 45 with acoustic signal, Pure white, 9010, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ÜSS 45-A-RW 6117465 OBO BETTERMANN Surge protection Modul 45 with acoustic signal, Pure white, 9010,

USS 45-A-RW

6117465

OBO BETTERMANN

1 Pcs.

Surge protection Modul 45 with acoustic signal, Pure white, 9010, Surge protection module for Modul 45 with audible signalling. Surge protection/network fine protection, type 3, according to EN 61643-11 for installation in Rapid 45 duct, device installation duct and underfloor systems. • Version-A with acoustic function display (switchable signal tone)• Quick and easy mounting• Low construction width of 22.5 mm• Colour: Pure white; RAL 9010 Application: The surge protective device secures downstream and nearby sockets.Surge protection device Type 3 (Class D) to VDE 0675 Parts 6−11 (DIN EN 61643-11)for installation in Rapid 45 trunking, device installation trunking and underfloor systems.

Automation > Surge protection device for terminal equipment
Surge , arrestor, type 3

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Arrester surge current (8/20 µs) [total]5 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,5421 kg CO2e / 1 Piece
ColourPure white; RAL 9010
Combined voltage protection level [L-PE]1500 kV
Conductor cross-section, rigid (single-wire/multiwire), max.1,5 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.1,5 mm²
Dimension255V
Installation typeModule
Lightning protection zone LPZ2→3
Max. mains-side overcurrent protection16
Maximum back-up fuse16 A
Maximum continuous voltage AC255 V
Maximum discharge current (8/20 μs)5 kA
Network formOther
Nominal discharge current (8/20 µs)2,5 kA
Nominal voltage AC (50/60 Hz)230 V
OBO_Nominal load current (input/output terminal)16 A
Operating temperature, max.45 °C
Operating temperature, min.-25 °C
Permitted temperature range, max.45 °C
Permitted temperature range, min.-25 °C
Protection level [L-N]≤1500
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceAcoustic
SPD to EN 61643-11Type 3
SPD to IEC 61643-1Class III
Test class, type 3yes
Version forAcoustic function display

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.