View larger
TD-2/D-HS 5081694 OBO BETTERMANN Surge protection device for TK systems with hat rail, White, Plastic
TD-2/D-HS
5081694
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Surge , arrestor, type 3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Obo Bettermann TD-2/D-HS surge protection device for TK systems with hat rail, White, Plastic provides reliable transient voltage suppression for telecommunications and data lines mounted on standard DIN rails. It effectively absorbs electrical disturbances to protect connected interface modules. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrestor monitoring: no
- Capacity (wire-earth): <50 pF
- Capacity (wire-wire): <50 pF
- CO2 Footprint (GWP) Cradle-to-Gate: 0,2096 kg CO2e / 1 Piece
- Colour: White
- Connection cross-section, flexible, max.: 2,5 mm²
- Connection cross-section, flexible, min.: 0,14 mm²
- Connection cross-section, multi-wire, max.: 2,5 mm²
- Connection cross-section, multi-wire, min.: 0,14 mm²
- Connection cross-section, rigid, max.: 2,5 mm²
- Connection cross-section, rigid, min.: 0,14 mm²
- Cut-off frequency: 75 MHz
- Dimension: 170V
- Division unit TE (17.5 mm): 1
- Earthing via:: Connection cable
- Explosion-tested: no
More info
▲| Arrestor monitoring | no |
|---|---|
| Capacity (wire-earth) | <50 pF |
| Capacity (wire-wire) | <50 pF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,2096 kg CO2e / 1 Piece |
| Colour | White |
| Connection cross-section, flexible, max. | 2,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 2,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Cut-off frequency | 75 MHz |
| Dimension | 170V |
| Division unit TE (17.5 mm) | 1 |
| Earthing via: | Connection cable |
| Explosion-tested version | no |
| Impulse durability wire-earth | C2: 18 kV / 9 kA (8/20µs) |
| Impulse durability wire-wire | C2: 18 kV / 9 kA (8/20µs) |
| Insertion loss | ≤3 dB |
| Insulation resistance | >1 MΩ |
| Kategorie | Type 1+2+3 / D1+C2+C1 |
| Lightning impulse current | 2,5 kA |
| Lightning protection zone LPZ | 0→3 |
|---|---|
| Material | Plastic |
| Maximum continuous voltage AC | 120 V |
| Maximum continuous voltage DC | 170 V |
| Nominal load current AC | 0,14 A |
| Nominal load current DC | 0,2 A |
| Number of poles | 2 |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-earth | <650 V |
| Protection level wire-wire | <300 V |
| Protection rating | IP20 |
| Screening | Direct |
| Series resistance per wire | 9 Ω ± 10 % |
| Shielding connection available | no |
| Signalling on device | Visual |
| SPD to IEC 61643-21 | Class I+II+III / D1+C2+C1 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (10/350) | D1: 5 kA |
| Total discharge current (8/20) | 10 kA |