OBO BETTERMANN MDP-4 D-5-T MDP-4 D-5-T 5098411 OBO BETTERMANN Lightning barrier 4-pole with test function, 5V, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MDP-4 D-5-T 5098411 OBO BETTERMANN Lightning barrier 4-pole with test function, 5V,

MDP-4 D-5-T

5098411

OBO BETTERMANN

1 Pcs.

Lightning barrier 4-pole with test function, 5V, Series protection device, 4-pole, 5 V version. Lightning barrier with test function; 5 V version • Nominal load current 0.58 A• Protection device for multi-wire systems• Direct shield earthing and screwless connection terminals• Space-saving width of just 8.7 mm • Protection circuit testable with Life Control• High frequency range of 0–100 MHz• UL-listed (4DG1) Application: Universal use on 35 mm DIN profile rail in any standard distribution housing.

Automation > Combined arrester for data networks/MCR-technology
Surge , arrestor, type 3

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A lightning barrier 4-pole with test function, 5V from Obo Bettermann, specifically model MDP-4 D-5-T, is a modular surge protection device utilized to protect instrumentation networks and data communication lines from destructive voltage spikes. These protective units are normally integrated into control infrastructure to limit transient surges and protect sensitive automation interfaces without disrupting ongoing signal traffic. Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Approvals: UL
  • Arrestor monitoring: no
  • Capacity (wire-wire): < 40 pF
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,2958 kg CO2e / 1 Piece
  • Connection cross-section, flexible, max.: 2,5 mm²
  • Connection cross-section, flexible, min.: 0,14 mm²
  • Connection cross-section, multi-wire, max.: 1,5 mm²
  • Connection cross-section, multi-wire, min.: 0,14 mm²
  • Connection cross-section, rigid, max.: 2,5 mm²
  • Connection cross-section, rigid, min.: 0,14 mm²
  • Cut-off frequency: 100 MHz
  • Dimension: 5V
  • Earthing via:: DIN rail
  • Explosion-tested version: no
  • Impulse durability wire-earth: C2: 5 kV / 2,5 kA (8/20µs)
  • Impulse durability wire-wire: C1: 0,5 kV / 0,25 kA (8/20µs)

More info

▲
ApprovalsUL
Arrestor monitoringno
Capacity (wire-wire)< 40 pF
CO2 Footprint (GWP) Cradle-to-Gate0,2958 kg CO2e / 1 Piece
Connection cross-section, flexible, max.2,5 mm²
Connection cross-section, flexible, min.0,14 mm²
Connection cross-section, multi-wire, max.1,5 mm²
Connection cross-section, multi-wire, min.0,14 mm²
Connection cross-section, rigid, max.2,5 mm²
Connection cross-section, rigid, min.0,14 mm²
Cut-off frequency100 MHz
Dimension5V
Earthing via:DIN rail
Explosion-tested versionno
Impulse durability wire-earthC2: 5 kV / 2,5 kA (8/20µs)
Impulse durability wire-wireC1: 0,5 kV / 0,25 kA (8/20µs)
Insertion loss≤3 dB
Insulation resistance>10 MΩ
KategorieType 1+2+3 / D1+C2+C1
Lightning protection zone LPZ0→3
Maximum continuous voltage AC7 V
Maximum continuous voltage DC10 V
Nominal load current AC0,4 A
Nominal load current DC0,58 A
Nominal voltage5 V
Number of poles4
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Plug-in systemTerminal
Protection level @ C1<50 V
Protection level wire-earth<800 V
Protection level wire-wire<35 V
Protection ratingIP20
ScreeningDirect
Series resistance per wire2,35 Ω ± 5 %
Shielding connection availableyes
Signalling on deviceReadable
SPD to IEC 61643-21Class I+II+III / D1+C2+C1
Telecommunications contactno
Testing standardIEC 61643-21
Total discharge current (10/350)D1: 2 kA
Total discharge current (8/20)10 kA

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.