View larger
MDP-4 D-5-T-10 5098413 OBO BETTERMANN Lightning barrier for high nominal currents, 5V,
MDP-4 D-5-T-10
5098413
OBO BETTERMANN
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Surge , arrestor, type 3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Obo Bettermann Lightning barrier for high nominal currents, 5V, part number MDP-4 D-5-T-10 is a heavy-duty surge suppression module designed to protect sensitive data and instrumentation lines handling significant operational currents from destructive transient overvoltages.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Approvals: UL
- Capacity (wire-wire): < 40 pF
- CO2 Footprint (GWP) Cradle-to-Gate: 0,2969 kg CO2e / 1 Piece
- Connection cross-section, flexible, max.: 2,5 mm²
- Connection cross-section, flexible, min.: 0,14 mm²
- Connection cross-section, multi-wire, max.: 1,5 mm²
- Connection cross-section, multi-wire, min.: 0,14 mm²
- Connection cross-section, rigid, max.: 2,5 mm²
- Connection cross-section, rigid, min.: 0,14 mm²
- Cut-off frequency: 100 MHz
- Dimension: 5V
- Earthing via:: DIN rail
- Impulse durability wire-wire: C1: 0,5 kV / 0,25 kA (8/20µs)
- Insertion loss: ≤3 dB
- Insulation resistance: >10 MΩ
- Kategorie: Type 1+2+3 / D1+C2+C1
More info
▲| Approvals | UL |
|---|---|
| Capacity (wire-wire) | < 40 pF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,2969 kg CO2e / 1 Piece |
| Connection cross-section, flexible, max. | 2,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 1,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Cut-off frequency | 100 MHz |
| Dimension | 5V |
| Earthing via: | DIN rail |
| Impulse durability wire-wire | C1: 0,5 kV / 0,25 kA (8/20µs) |
| Insertion loss | ≤3 dB |
| Insulation resistance | >10 MΩ |
| Kategorie | Type 1+2+3 / D1+C2+C1 |
| Lightning impulse current | 2 kA |
| Lightning protection zone LPZ | 0→3 |
| Maximum continuous voltage AC | 7 V |
| Maximum continuous voltage DC | 10 V |
|---|---|
| Nominal load current AC | 0,7 A |
| Nominal load current DC | 10 A |
| Nominal voltage | 5 V |
| Number of poles | 4 |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-earth | <800 V |
| Protection level wire-wire | <45 V |
| Protection rating | IP20 |
| Screening | Direct |
| Shielding connection available | yes |
| Signalling on device | Readable |
| SPD to IEC 61643-21 | Class I+II+III / D1+C2+C1 |
| Testing standard | IEC 61643-21 |
| Total discharge current (10/350) | D1: 2 kA |
| Total discharge current (8/20) | 10 kA |