OBO BETTERMANN FRD 24 FRD 24 5098514 OBO BETTERMANN Lightning barrier with decoupling resistance, 24V AC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FRD 24 5098514 OBO BETTERMANN Lightning barrier with decoupling resistance, 24V AC,

FRD 24

5098514

OBO BETTERMANN

1 Pcs.

Lightning barrier with decoupling resistance, 24V AC, Medium and fine protection FRD for two-core systems 24 V. Surge protection for use in measurement and control technology • Medium and fine protection • Standard design for double core systems • Two-stage protection circuit • With installation-friendly, screwless connection terminals • In space-saving 17.5 mm grid • With ohmic decoupling in the longitudinal branchApplication: Universal use on any 35 mm DIN profile rail in every commercially available distributor housing.

Automation > Combined arrester for data networks/MCR-technology
Surge , arrestor, type 3

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Obo Bettermann lightning barrier (part number FRD 24) is designed to divert transient surges and protect sensitive automation instruments from line-borne voltage spikes. Such protective components are commonly installed in industrial control architectures to ensure continuous, safe operation of signal circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Approvals: UL
  • Arrestor monitoring: no
  • Capacity (wire-earth): <1 nF
  • Capacity (wire-wire): <10 nF
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,2657 kg CO2e / 1 Piece
  • Connection cross-section, flexible, max.: 2,5 mm²
  • Connection cross-section, flexible, min.: 0,14 mm²
  • Connection cross-section, multi-wire, max.: 2,5 mm²
  • Connection cross-section, multi-wire, min.: 0,14 mm²
  • Connection cross-section, rigid, max.: 2,5 mm²
  • Connection cross-section, rigid, min.: 0,14 mm²
  • Cut-off frequency: 1,1 MHz
  • Dimension: 24V AC
  • Division unit TE (17.5 mm): 1
  • Earthing via:: Terminal
  • Explosion-tested version: no

More info

▲
ApprovalsUL
Arrestor monitoringno
Capacity (wire-earth)<1 nF
Capacity (wire-wire)<10 nF
CO2 Footprint (GWP) Cradle-to-Gate0,2657 kg CO2e / 1 Piece
Connection cross-section, flexible, max.2,5 mm²
Connection cross-section, flexible, min.0,14 mm²
Connection cross-section, multi-wire, max.2,5 mm²
Connection cross-section, multi-wire, min.0,14 mm²
Connection cross-section, rigid, max.2,5 mm²
Connection cross-section, rigid, min.0,14 mm²
Cut-off frequency1,1 MHz
Dimension24V AC
Division unit TE (17.5 mm)1
Earthing via:Terminal
Explosion-tested versionno
Impulse durability wire-earthC2: 10 kV / 5 kA (8/20µs)
Impulse durability wire-wireC2: 5 kV / 2,5 kA (8/20µs)
Insertion loss3 dB @ 1,1 MHz dB
Insulation resistance>1 MΩ
KategorieType 1+2+3 / D1+C2+C1
Lightning impulse current1,5 kA
Lightning protection zone LPZ0→3
Maximum continuous voltage AC19 V
Maximum continuous voltage DC28 V
Nominal discharge current (8/20 µs)5 kA
Nominal load current AC0,14 A
Nominal load current DC0,2 A
Nominal voltage24 V
Number of poles2
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Plug-in systemTerminal
Protection level wire-earth<600 V
Protection level wire-wire<60 V
Protection ratingIP20
Series resistance per wire15 Ω ± 10 %
Shielding connection availableno
SPD to IEC 61643-21Class I+II+III / D1+C2+C1
Telecommunications contactno
Testing standardIEC 61643-21
Total discharge current (10/350)D1: 3 kA
Total discharge current (8/20)10 kA

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.