View larger
FRD 2-24 5098727 OBO BETTERMANN Lightning barrier with decoupling resistance, 24V AC,
FRD 2-24
5098727
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for data networks/MCR-technology
Surge , arrestor, type 3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Obo Bettermann FRD 2-24 lightning barrier with decoupling resistance, 24V AC functions as an electrical protection unit designed to limit high-voltage transients on industrial instrumentation loops. These suppressors are typically wired into control cabinets to absorb incoming electrical surges and protect delicate connected equipment from failure. Final pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrestor monitoring: no
- Capacity (wire-earth): <10 nF
- Capacity (wire-wire): <10 nF
- CO2 Footprint (GWP) Cradle-to-Gate: 0,3121 kg CO2e / 1 Piece
- Connection cross-section, flexible, max.: 2,5 mm²
- Connection cross-section, flexible, min.: 0,14 mm²
- Connection cross-section, multi-wire, max.: 2,5 mm²
- Connection cross-section, multi-wire, min.: 0,14 mm²
- Connection cross-section, rigid, max.: 2,5 mm²
- Connection cross-section, rigid, min.: 0,14 mm²
- Dimension: 24V AC
- Division unit TE (17.5 mm): 1
- Earthing via:: Terminal
- Explosion-tested version: no
- Impulse durability wire-earth: C2: 5 kV / 2,5 kA (8/20µs)
- Impulse durability wire-wire: C2: 5 kV / 2,5 kA (8/20µs)
More info
▲| Arrestor monitoring | no |
|---|---|
| Capacity (wire-earth) | <10 nF |
| Capacity (wire-wire) | <10 nF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,3121 kg CO2e / 1 Piece |
| Connection cross-section, flexible, max. | 2,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 2,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Dimension | 24V AC |
| Division unit TE (17.5 mm) | 1 |
| Earthing via: | Terminal |
| Explosion-tested version | no |
| Impulse durability wire-earth | C2: 5 kV / 2,5 kA (8/20µs) |
| Impulse durability wire-wire | C2: 5 kV / 2,5 kA (8/20µs) |
| Insertion loss | 3 dB @ 1 MHz dB |
| Insulation resistance | >10 MΩ |
| Kategorie | Type 2+3 / C2+C1 |
| Lightning protection zone LPZ | 1→3 |
| Maximum continuous voltage AC | 19 V |
|---|---|
| Maximum continuous voltage DC | 28 V |
| Nominal discharge current (8/20 µs) | 2,5 kA |
| Nominal load current AC | 0,14 A |
| Nominal load current DC | 0,2 A |
| Nominal voltage | 24 V |
| Number of poles | 2 |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-earth | <60 V |
| Protection level wire-wire | <120 V |
| Protection rating | IP20 |
| Series resistance per wire | 15 Ω ± 10 % |
| Shielding connection available | no |
| SPD to IEC 61643-21 | Class II+III / C2+C1 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (8/20) | 5 kA |