OBO BETTERMANN FRD 2-24 FRD 2-24 5098727 OBO BETTERMANN Lightning barrier with decoupling resistance, 24V AC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FRD 2-24 5098727 OBO BETTERMANN Lightning barrier with decoupling resistance, 24V AC,

FRD 2-24

5098727

OBO BETTERMANN

1 Pcs.

Lightning barrier with decoupling resistance, 24V AC, Medium and fine protection FRD 2 for two-core systems 24 V. Surge protection for use in measurement and control technology • Medium and fine protection • Standard design for double core systems • Two-stage protection circuit • With installation-friendly, screwless connection terminals • In space-saving 17.5 mm grid • With ohmic decoupling in the longitudinal branchApplication: Universal use on any 35 mm DIN profile rail in every commercially available distributor housing.

Automation > Combined arrester for data networks/MCR-technology
Surge , arrestor, type 3

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Obo Bettermann FRD 2-24 lightning barrier with decoupling resistance, 24V AC functions as an electrical protection unit designed to limit high-voltage transients on industrial instrumentation loops. These suppressors are typically wired into control cabinets to absorb incoming electrical surges and protect delicate connected equipment from failure. Final pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Arrestor monitoring: no
  • Capacity (wire-earth): <10 nF
  • Capacity (wire-wire): <10 nF
  • CO2 Footprint (GWP) Cradle-to-Gate: 0,3121 kg CO2e / 1 Piece
  • Connection cross-section, flexible, max.: 2,5 mm²
  • Connection cross-section, flexible, min.: 0,14 mm²
  • Connection cross-section, multi-wire, max.: 2,5 mm²
  • Connection cross-section, multi-wire, min.: 0,14 mm²
  • Connection cross-section, rigid, max.: 2,5 mm²
  • Connection cross-section, rigid, min.: 0,14 mm²
  • Dimension: 24V AC
  • Division unit TE (17.5 mm): 1
  • Earthing via:: Terminal
  • Explosion-tested version: no
  • Impulse durability wire-earth: C2: 5 kV / 2,5 kA (8/20µs)
  • Impulse durability wire-wire: C2: 5 kV / 2,5 kA (8/20µs)

More info

▲
Arrestor monitoringno
Capacity (wire-earth)<10 nF
Capacity (wire-wire)<10 nF
CO2 Footprint (GWP) Cradle-to-Gate0,3121 kg CO2e / 1 Piece
Connection cross-section, flexible, max.2,5 mm²
Connection cross-section, flexible, min.0,14 mm²
Connection cross-section, multi-wire, max.2,5 mm²
Connection cross-section, multi-wire, min.0,14 mm²
Connection cross-section, rigid, max.2,5 mm²
Connection cross-section, rigid, min.0,14 mm²
Dimension24V AC
Division unit TE (17.5 mm)1
Earthing via:Terminal
Explosion-tested versionno
Impulse durability wire-earthC2: 5 kV / 2,5 kA (8/20µs)
Impulse durability wire-wireC2: 5 kV / 2,5 kA (8/20µs)
Insertion loss3 dB @ 1 MHz dB
Insulation resistance>10 MΩ
KategorieType 2+3 / C2+C1
Lightning protection zone LPZ1→3
Maximum continuous voltage AC19 V
Maximum continuous voltage DC28 V
Nominal discharge current (8/20 µs)2,5 kA
Nominal load current AC0,14 A
Nominal load current DC0,2 A
Nominal voltage24 V
Number of poles2
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Plug-in systemTerminal
Protection level wire-earth<60 V
Protection level wire-wire<120 V
Protection ratingIP20
Series resistance per wire15 Ω ± 10 %
Shielding connection availableno
SPD to IEC 61643-21Class II+III / C2+C1
Telecommunications contactno
Testing standardIEC 61643-21
Total discharge current (8/20)5 kA

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.