FRD 110 5098557 OBO BETTERMANN Lightning barrier with decoupling resistance, 110V AC,
FRD 110
5098557
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for data networks/MCR-technology
Surge , arrestor, type 3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Protect sensitive instrumentation and low-voltage electrical circuits against high-energy surges using the FRD 110 5098557 OBO BETTERMANN Lightning barrier with decoupling resistance, 110V AC,. Lightning barriers and surge arresters are installed within distribution boards and signal pathways to divert dangerous transient overvoltages safely to ground before they can damage downstream electronics. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Approvals: UL
- Arrestor monitoring: no
- Capacity (wire-earth): <1 nF
- Capacity (wire-wire): <10 nF
- CO2 Footprint (GWP) Cradle-to-Gate: 0,1805 kg CO2e / 1 Piece
- Connection cross-section, flexible, max.: 2,5 mm²
- Connection cross-section, flexible, min.: 0,14 mm²
- Connection cross-section, multi-wire, max.: 2,5 mm²
- Connection cross-section, multi-wire, min.: 0,14 mm²
- Connection cross-section, rigid, max.: 2,5 mm²
- Connection cross-section, rigid, min.: 0,14 mm²
- Cut-off frequency: 3,6 MHz
- Dimension: 110V AC
- Division unit TE (17.5 mm): 1
- Earthing via:: Terminal
- Explosion-tested version: no
More info
▲| Approvals | UL |
|---|---|
| Arrestor monitoring | no |
| Capacity (wire-earth) | <1 nF |
| Capacity (wire-wire) | <10 nF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,1805 kg CO2e / 1 Piece |
| Connection cross-section, flexible, max. | 2,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 2,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Cut-off frequency | 3,6 MHz |
| Dimension | 110V AC |
| Division unit TE (17.5 mm) | 1 |
| Earthing via: | Terminal |
| Explosion-tested version | no |
| Impulse durability wire-earth | C2: 10 kV / 5 kA |
| Impulse durability wire-wire | C2: 5 kV / 2,5 kA (8/20µs) |
| Insertion loss | 3 dB @ 3,6 MHz dB |
| Insulation resistance | >100 MΩ |
| Kategorie | Type 1+2+3 / D1+C2+C1 |
| Lightning impulse current | 1,5 kA |
| Lightning protection zone LPZ | 0→3 |
|---|---|
| Maximum continuous voltage AC | 86 V |
| Maximum continuous voltage DC | 122 V |
| Nominal discharge current (8/20 µs) | 5 kA |
| Nominal load current AC | 0,14 A |
| Nominal load current DC | 0,2 A |
| Nominal voltage | 110 V |
| Number of poles | 2 |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-earth | <600 V |
| Protection level wire-wire | <300 V |
| Protection rating | IP20 |
| Series resistance per wire | 15 Ω ± 10 % |
| Shielding connection available | no |
| SPD to IEC 61643-21 | Class I+II+III / D1+C2+C1 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (10/350) | D1: 3 kA |
| Total discharge current (8/20) | 10 kA |