A lightning barrier with decoupling inductivity, 24V AC manufactured by Obo Bettermann as model FLD 2-24 functions as a protective device configured to safeguard measurement and control equipment from harmful electrical surges. Industrial installations use these components to protect vital communications circuits against indirect lightning strikes and high-voltage transients. Final pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Approvals: UL
- Capacity (wire-earth): <10 nF
- Capacity (wire-wire): <10 nF
- CO2 Footprint (GWP) Cradle-to-Gate: 0,295 kg CO2e / 1 Piece
- Connection cross-section, flexible, max.: 2,5 mm²
- Connection cross-section, flexible, min.: 0,14 mm²
- Connection cross-section, multi-wire, max.: 2,5 mm²
- Connection cross-section, multi-wire, min.: 0,14 mm²
- Connection cross-section, rigid, max.: 2,5 mm²
- Connection cross-section, rigid, min.: 0,14 mm²
- Dimension: 24V AC
- Division unit TE (17.5 mm): 1
- Earthing via:: Terminal
- Explosion-tested version: no
- Impulse durability wire-earth: C1: 1 kV / 0,5 kA (8/20µs)
- Impulse durability wire-wire: C1: 1 kV / 0,5 kA (8/20µs)
More info
▲| Approvals | UL |
|---|---|
| Capacity (wire-earth) | <10 nF |
| Capacity (wire-wire) | <10 nF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,295 kg CO2e / 1 Piece |
| Connection cross-section, flexible, max. | 2,5 mm² |
| Connection cross-section, flexible, min. | 0,14 mm² |
| Connection cross-section, multi-wire, max. | 2,5 mm² |
| Connection cross-section, multi-wire, min. | 0,14 mm² |
| Connection cross-section, rigid, max. | 2,5 mm² |
| Connection cross-section, rigid, min. | 0,14 mm² |
| Dimension | 24V AC |
| Division unit TE (17.5 mm) | 1 |
| Earthing via: | Terminal |
| Explosion-tested version | no |
| Impulse durability wire-earth | C1: 1 kV / 0,5 kA (8/20µs) |
| Impulse durability wire-wire | C1: 1 kV / 0,5 kA (8/20µs) |
| Insertion loss | 3dB @ 150 kHz dB |
| Insulation resistance | > 10 MΩ |
| Kategorie | Type 2+3 / C2+C1 |
| Lightning protection zone LPZ | 1→3 |
|---|---|
| Maximum continuous voltage AC | 19 V |
| Maximum continuous voltage DC | 28 V |
| Nominal discharge current (8/20 µs) | 0,5 kA |
| Nominal load current AC | 0,7 A |
| Nominal load current DC | 1 A |
| Number of poles | 2 |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | Terminal |
| Protection level wire-earth | <60 V |
| Protection level wire-wire | <120 V |
| Protection rating | IP20 |
| Series inductivity per wire | 120 µH ± 10 % |
| Shielding connection available | no |
| SPD to IEC 61643-21 | Class II+III / C2+C1 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (8/20) | 1 kA |