DS-N M/W 5093996 OBO BETTERMANN Protection device for high-frequency cables, 130V,
DS-N M/W
5093996
OBO BETTERMANN
1 Pcs.
Automation > Combined arrester for data networks/MCR-technology
Surge , arrestor, type 3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A protection device for high-frequency cables, 130V from Obo Bettermann designated as DS-N M/W provides dedicated surge suppression for coaxial and RF communication lines. Telecommunications and industrial network setups utilize these high-frequency suppressors to protect sensitive transceivers from lightning surges and electrical noise. Final pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Arrestor monitoring: no
- Capacity (wire-earth): <20 pF
- Capacity (wire-wire): <10 pF
- CO2 Footprint (GWP) Cradle-to-Gate: 0,0659 kg CO2e / 1 Piece
- Cut-off frequency: 3000 MHz
- Dimension: 130V
- Explosion-tested version: no
- Impulse durability wire-earth: C2: 10 kV / 5 kA (8/20µs)
- Impulse durability wire-wire: C2: 10 kV / 5 kA (8/20µs)
- Insertion loss: ≤0,62 dB
- Insulation resistance: >1 GΩ
- Kategorie: Type 1+2 / D1+C2
- Lightning impulse current: 2,5 kA
- Lightning protection zone LPZ: 0→2
- Maximum continuous voltage AC: 130 V
- Maximum continuous voltage DC: 185 V
More info
▲| Arrestor monitoring | no |
|---|---|
| Capacity (wire-earth) | <20 pF |
| Capacity (wire-wire) | <10 pF |
| CO2 Footprint (GWP) Cradle-to-Gate | 0,0659 kg CO2e / 1 Piece |
| Cut-off frequency | 3000 MHz |
| Dimension | 130V |
| Explosion-tested version | no |
| Impulse durability wire-earth | C2: 10 kV / 5 kA (8/20µs) |
| Impulse durability wire-wire | C2: 10 kV / 5 kA (8/20µs) |
| Insertion loss | ≤0,62 dB |
| Insulation resistance | >1 GΩ |
| Kategorie | Type 1+2 / D1+C2 |
| Lightning impulse current | 2,5 kA |
| Lightning protection zone LPZ | 0→2 |
| Maximum continuous voltage AC | 130 V |
| Maximum continuous voltage DC | 185 V |
| Nominal load current AC | 7 A |
| Nominal load current DC | 10 A |
| Number of poles | 1 |
|---|---|
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Plug-in system | N |
| Protection level | <800 V |
| Protection level wire-earth | <800 V |
| Protection level wire-wire | <800 V |
| Protection rating | IP40 |
| Return loss | ≥14 dB |
| Screening | Direct |
| Shielding connection available | yes |
| Signalling on device | None |
| SPD to IEC 61643-21 | Class I+II / D1+C2 |
| Telecommunications contact | no |
| Testing standard | IEC 61643-21 |
| Total discharge current (10/350) | 5 kA |
| Total discharge current (8/20) | 10 kA |
| Wave resistance | 50 Ω |